Kaba COMBI B30 Manuel D'utilisation page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.5 Deleting user code
In contrast to blocking the code is irretrievably lost after deletion. To use it again, it has to be activated again.
Blocked codes can be deleted without previous releasing.
Step
Enter P
1.
Enter your valid master code, e.g. 00678912 and press enter
2.
Press P4 and enter
3.
Enter the ID to be deleted and press enter e.g. user 15
4.
(ID = 01 to 30 for user)
The user is deleted
5.
3. Time delay and opening window
3.1 Adjusting the time delay and opening window
Time delay 01 - 99 minutes:
time to wait until the lock can be opened.
Opening window 01 - 19 minutes:
Within this time window the master or the user can open the lock with his code.
Step
Press P
1.
Enter your 8-digit master code, e.g. 00678912 and press enter
2.
Press P2 and enter
3.
Enter the time delay e.g. 20 minutes
4.
Enter the opening window e.g. 10 minutes
5.
Press enter
6.
22
Action
Code input – beginning of the time delay
Wait during the time delay
Opening window – re-enter code
Action
Key
P
00678912
P5
15
Key
P
00678912
P2
20
10