8. Power supply

8.1 Battery replacement

When battery voltage is insufficient, after entering the code a warning tone occurs repeatedly and the red LEDs
flash alternately. Only batteries of type AAA can be used. It is highly recommended to use high-quality brand
batteries and replace them as a precaution every 24 months at the latest.
Step
Note the position of the rotary handle (marking)
1.
Allen wrench into the small hole on the bottom side and press it in to the stop
2.
Remove the rotary handle to the front, while keeping the Allen wrench pressed
3.
Remove the Allen wrench
4.
Loosen and remove the screw
5.
Move the top part of the input unit in the direction of the arrow to the stop
6.
Remove the top part of the input unit carefully
7.
Replacing the batteries. Mounting in the reverse order
8.
Attach the screw to secure the top part
9.
Attach the rotary handle in the position in which it has been mounted before dismounting
10.
Finally, the security block out message must be neutralised. Read chapter 7.2 for further
11.
information