Always disconnect the charger from the power supply if not
in use.
The standard rechargeable battery (EX) and the long-life
rechargeable battery (EX) may only be charged using the
Dräger X-plore 8000 standard charger (component list
pos. 7).
Charging the battery:
1. Check to make sure that voltage of mains supply is
correct. The operational voltage of the power supply unit
must match the mains supply voltage.
2. Connect charger to power supply unit.
3. Connect the power supply unit to the mains supply.
4. First position the rechargeable battery at an angle in the
charger and then fold it in until it snaps audibly into place.
5. Wait for the end of the charging process.
6. When the rechargeable battery is fully charged, push the
battery lock button and remove the battery.
7. Disconnect the power supply unit and charger from the
mains supply.

5.3.3 Replacing the filter

WARNING
No protection without filter!
► Do not use the device without filter.
CAUTION
Damage to blower unit due to penetration of particles!
► Make sure when you remove the filter that no particles
enter the device through the suction inlet.
The filter changing process may differ depending on the
filter type used.
Particle filter
Removing the filter:
1. Push filter lock button.
2. Fold out splash guard cover with filter (figure A).
3. Remove used filter (figure B).
Inserting the filter:
1. Check rubber seal on filter for damage.
2. Insert new filter into splash guard cover so that the filter is
firmly seated in the splash guard cover.
3. Hook the two lower connection points of the splash guard
cover at an angle into the blower unit sockets.
4. Fold splash guard cover in until it audibly snaps into place
at the filter lock button.
Instructions for use
|
Dräger X-plore® 8000
A
Gas or combination filter
Removing the filter:
1. Push filter lock button.
2. Fold filter with splash guard cover out (figure A).
3. Dismantling the splash guard cover:
a. Press on the centre of the upper splash guard cover
edge until it snaps out.
b. Fold out splash guard cover (figure B).
Inserting the filter:
1. Check rubber seal on filter for damage.
2. Place splash guard cover with its lower edge at an angle
on the filter.
3. Push on splash guard cover until it snaps audibly into
place.
4. Hook the two lower connection points of the filter at an
angle into the blower unit sockets.
5. Fold filter in until it audibly snaps into place at the filter lock
button.

5.3.4 Check the flow rate and warning devices

1. Make sure that a filter is inserted.
2. Connect the plug-in connector of the breathing hose to the
blower unit.
3. Switch on the blower unit by pushing the
control panel for approx. 2 seconds.
 After it is switched on, the device performs a self-test.
If the device does not work properly or warning
devices are triggered, eliminate the fault.
4. Cover the open end of the breathing hose with the palm of
your hand.
 The blower unit starts operating more intensively after
about 5 seconds. An alarm is triggered after about
B
20 seconds.
Have the blower unit checked if the rotational speed
remains unchanged and no alarm is triggered.
5. If you wish, you can switch off the blower unit by pushing
the
button on the control panel once again.
5.3.5 Replacing the O-ring at plug-in or bayonet-
type hose connector
1. Use the O-ring removal tool to lift the old O-ring out of the
groove.
2. Insert new O-ring in the provided groove.
6

Transport

Transport in the original packaging or in optionally available
transport box.
Transport