7. TECHNICAL DATA
Input data
Measuring principle
Measuring range
Probe length
Probe diameter
Pressure resistance
Overload pressure
Mechanical connection
Torque value
Parts in contact with medium
Output data
Output signal, permitted load resistance
Accuracy (at room temperature)
Temperature drift (environment))
Rise time to DIN EN 60751
Ambient conditions
Ambient temperature range
Storage temperature range
Fluid temperature range
- mark
2)
-mark
Vibration resistance to
DIN EN 60068-2-6 at 10 ..500 Hz
Protection class to DIN 40050
Other data
Supply voltage
For use acc. to UL spec.
Residual ripple of supply voltage
Current consumption
Weight
Note
Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are
provided.
FS (Full Scale) = relative to the full measuring range
1) -25°C with FPM seal, -40°C on request
2) Environmental conditions according to 1.4.2 UL 61010-1; C22.2 No. 61010-1
All details in this brochure are subject to technical modifications.
Stand: 17.04.2013
1)
HYDAC ELECTRONIC GMBH
Silicon semiconductor device
-25 .. +100 °C
10 mm
6.7 mm
600 bar
900 bar
G1/4 A DIN 3852
20 Nm
Mech. connection:
Seal:
FPM
4 .. 20 mA, 2 conductor
R
.= (U
- 8 V) / 20 mA [kΩ]
Lmax
B
0 .. 10 V, 3 conductor
R
2 kΩ
Lmin.=
≤ ± 1.0 % FS typ.
≤ ± 2.0 % FS max.
≤ ± 0.02 % FS / °C
t
: 4s
50
t
: 8s
90
-25 .. +80°C
-40 .. +100 °C
-40 .. +100 °C / -25 .. +100
EN 61000-6-1 / 2 / 3 / 4
Certificate No.: E318391
≤ 20 g
IP 67 (M12x1, when an IP 67 connector is
used)
8 .. 30 V DC 2 conductor
12 .. 30 V DC 3 conductor
-limited energy- according to
9.3 UL 61010,Class2;
UL 1310/1585;LPS UL 60950
≤ 5 %
< 25 mA
~ 60 g
ETS 7200
Stainless steel
Mat. Nr.: 669682 D/E/F