For wired or radio-networked (if equipped with optional radio
module) smoke alarm devices
The signals generated by the smoke alarm device that triggers the alarm
are as described above. The other smoke alarm devices will also emit
the following signals:
Acoustic signal
Loud intermittent
signal 85 dB(A)
2 short signals
in 60-sec. cycle
1-sec. continuous
alarm signal
73 dB(A) followed
by 2 s pause
5
Battery test – Changing the battery
The smoke detector is powered from a 9 V block battery (if a 230 V base
is used, then only when there is an interruption to the mains power). The
battery test automatically checks the supply voltage at regular intervals. If
the battery voltage drops below a defined level, the smoke alarm device
signals for 30 days that the battery has to be replaced. The smoke alarm
device is completely functional during this period.
36
Light ring
-
-
-
Meaning
Alarm at networked smoke
detectors - smoke or heat
only for wireless networks:
Battery change due
(remote signal)
Function test (remote signal),
activated by pressing the function
button for at least 4 s (Section 7)