6950.book Seite 9 Montag, 29. November 2004 12:54 12
7.7

Tool change with Futuro Plus keyless

chuck (not KHE-D 24, BHE-D 24)
Insert tool. Grip the retaining ring (a) firmly and,
with the other hand, turn sleeve (b) towards "GRIP,
ZU", until the mechanical resistance which can be
felt is overcome.
Caution! The chuck is not yet fully tightened! Keep
turning (there is a "clicking" sound while turning),
until further turning is no longer possible - only now
is the tool securely tightened.
With a soft tool shank, retightening may be
required after a short period of operation.
Opening the drill chuck:
Grip the retaining ring (a) firmly and, with the other
hand, turn the sleeve (b) towards "AUF,
RELEASE".
Note: The ratchet sound which can possibly be
heard after opening the drill chuck, is functional
and is switched off by a reverse rotation of the
sleeve.
If the chuck is extremely tightened:
Unplug. Hold drill chuck with an open end spanner
at the flats on its head and turn the sleeve (b) hard
towards "AUF, RELEASE".

8 Tips and Tricks

Only moderate pressure is required for hammer
drilling and chiselling. Exerting a high force does
not increase performance.
When drilling deep holes, remove the drill bit
periodically from the hole to release the stone
dust.
Drill tiles and other brittle materials without impact.

9 Maintenance

Keyless chuck cleaning:
After prolonged use hold the chuck vertically, with
the opening down, and fully open and close it
several times. The dust collected falls from the
opening. The application of cleaning spray to the
jaws and jaw openings at regular intervals is
recommended.
The vent slots of the machine should be cleaned
from time to time.

10 Trouble Shooting

If the trigger (11) can not be depressed, check to
see that the direction of rotation selector switch (9)
is fully set to the R or L position.
Electronic signal indicator (8) with VTC
electronics (KHE-D 28)
Flashing - carbon brushes worn
The carbon brushes are almost completely worn. If
the brushes are completely worn, the machine
switches off automatically. Have the brushes
replaced by an authorized service centre.
f

11 Accessories

Use only genuine Metabo accessories.
If you need accessories, check with your dealer.
For the dealer to select the correct accessory, he
needs to know the exact model designation of
your power tool.
See page 4.
A Tools with SDS-Plus shank
B Twist drills for metal and wood
C Dust extraction kit
D Special Grease

12 Repairs

Repairs to electrical tools must be carried out by
qualified electricians ONLY!
Any Metabo power tool in need of repair can be
sent to one of the addresses listed in the spare
parts list.
Please attach a description of the fault to the
power tool.
13 Environmetal Protection
Metabo's packaging can be 100% recycled.
Worn out power tools and accessories contain
considerable amounts of valuable raw and plastic
materials, which can be recycled.
These instructions are printed on chlorine-free
bleached paper.
ENGLISH
ENG
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Khe-d 24Khe-d 28

Table des Matières