Riello Burners Gulliver BLU BG1 Manuel D'entretien page 33

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INDEX
1.
BURNER DESCRIPTION . . . . . . . . . . . .
1.1 Burner equipment . . . . . . . . . . . . . . . . .
2.
TECHNICAL DATA . . . . . . . . . . . . . . . .
2.1 Technical data . . . . . . . . . . . . . . . . . . . .
2.2 Overall dimensions. . . . . . . . . . . . . . . . .
2.3 Working field . . . . . . . . . . . . . . . . . . . . .
3.
INSTALLATION . . . . . . . . . . . . . . . . . . .
3.1 Boiler fixing . . . . . . . . . . . . . . . . . . . . . .
3.2 Fuel supply . . . . . . . . . . . . . . . . . . . . . .
3.3 Hydraulic systems . . . . . . . . . . . . . . . . .
3.4 Electrical wiring . . . . . . . . . . . . . . . . . . .
1.
BURNER DESCRIPTION
One stage light oil burner with low pollutant emissions (Nitric Oxide NOx, Carbon monoxide CO and unburnt
Hydrocarbons), in conformity with the environmental mark "Blauer Engel" RAL-UZ9, Edition February 2001.
The burner has a device (compensator) which is integral with the air damper that sets the air output. This device
keeps the oxigen level as necessary for the combustion despite any changing of the room temperature.
The dimension of the boiler's combustion chamber must respond to specific
values, in order to guarantee a combustion with the lowest polluting
emissions rate.
The RIELLO Technical Service Personnel will be glad to give
you all the imformation for a correct matching of this
burner to the boiler.
1 – Oil pump
2 – Air damper adjustment
assembly
3 – Nozzle holder assembly
4 – Flange with insulating gasket
5 – Control-box
6 – Reset button with lock-out lamp
7 – Flame detector
8 – Temperature probe of the
compensator
The burner meets protection level of IP 40, EN 60529.
Burner with CE marking in conformity with EEC directives: EMC 89/336/EEC, Low Voltage 73/23/EEC,
Machines 98/37/EEC and Efficiency 92/42/EEC.
CE Certification No.: 0036 0264/99 (371T1) – 0036 0265/99 (372T1) – 0036 0266/99 (373T1), as 92/42/EEC.
BUWAL approval No. 192016 (371T1- 372T2).
1.1 BURNER EQUIPMENT
Flange with insulating gasket . . . .No. 1
Screw and nuts for flange . . . . . .No. 1
2318
1
4.
WORKING . . . . . . . . . . . . . . . . . . . . . . .
1
4.1 Combustion adjustment. . . . . . . . . . . . . .
4.2 Electrodes adjustment. . . . . . . . . . . . . . .
2
4.3 Flame detector adjustment . . . . . . . . . . .
2
4.4 Fuel heating . . . . . . . . . . . . . . . . . . . . . .
2
4.5 Burner start-up cycle. . . . . . . . . . . . . . . .
2
5.
MAINTENANCE . . . . . . . . . . . . . . . . . . .
3
3
6.
FAULTS / SOLUTIONS . . . . . . . . . . . . . . 10
3
4
5
Fig. 1
Screw and nuts for flange to be fixed to boiler . . . No. 4
Flexible oil pipes with nipples . . . . . . . . . . . . . . . . No. 2
1
GB
6
6
8
8
8
9
9

Publicité

Table des Matières
loading