Examples
With pulse operation
Connect the power supply unit of the pump up to
the socket. LED (2) "Pump on" will light up red.
Set the "Pulse" knob (1) to middle position. LED (4)
and LED (5) will light up alternately for approx. 3
seconds.
Use the "Power 1" knob (6) to set the higher pump
performance (e.g. 100 per cent).
Use the "Power 2" knob (7) to set the lower pump
performance (e.g. 30 per cent).
The pump will now change to and fro between
the two performances. The LEDs (4) and (5) will
indicate the current performance of the pump.
Without pulse operation
Use the knobs (6( and (7) „power 1" / „power 2" to
set the requested performance (e.g. 50 per cent) in
the same position.
The pump will now operate continuously with the
performance set in „power 1" (6) and „power 2" (7);
LED (5) and LED (4) light up alternately.
Exemples
Avec pulsations
Raccordez l'alimentation de la pompe sur le secteur,
la LED (2) " PUMP ON " s'allume
Réglez le bouton " PULSE " (1) en position centrale,
les LED (4) et LED (5) s'allument alternativement
avec une période de 3 secondes
Réglez la puissance maximale (100%) sur bouton
" POWER 1 " (6)
Réglez la puissance minimale (30 %) sur bouton
" POWER 2 " (7)
La pompe délivre alors une puissance alternant de
manière cyclique entre 100 et 30 %. L'état des LED
(4) et (5) indique l'état instantané de puissance de
la pompe.
Sans pulsations
Sur les bouton (6) et (7) „power 1" / „power 2", réglez
la puissance souhaitée (par ex. 50%) à des niveau
équivalents. La pompe fonctionne désormais en
puissance fixe suivant „power 1" (6) et „power 2" (7),
les LED (5) et LED (4) poursuivent leur pulsation.