Télécharger Imprimer la page

Roller Grill PL 400 G Notice D'installation page 16

Publicité

Les langues disponibles

Les langues disponibles

Check the supply pressure using a manometer when all the burners are lit. It must be
equal to the indications on the rating plate.
The fresh air flow required for combustion air supply is:
- PL 400 G
5.5 m3/h
- PL 600 G
11.0 m3/h
General conditions of installation
The installation and maintenance of the appliance must be carried out in compliance
with the statutory texts and good practices in force, mainly:
General specifications
For all appliances:
Article GZ Installation with combustible gases and liquefied hydrocarbons.
Then, according to use:
Article CH Heating, ventilation, refrigeration
Air conditioning and domestic hot water steam generation.
Important: Never change the diameter of the injectors.
Gas category table, according to the country of destination of the appliance.
Country of destination
France/ Luxembourg
Germany
Austria
Belgium
Sweden/Denmark/Finland
Spain
Netherlands
Norway
Iceland/Greece/United King-
dom/Italy/Portugal
Category
Gas
I 3+
G30/G31
I 3B/P
G30/G31
I 3B/P
G30/G31
I 3B/P
G30/G31
I 3+
G30/G31
I 3B/P
G30/G31
I 3+
G30/G31
I 3P
G31
I 3B/P
G30/G31
I 3P
G31
I3B/P
G30/G31
I 3+
G30/G31
Pressure
Injector diam-
eter
28-30/37
Ø 85
50
Ø 85
50
Ø 85
50
Ø 85
28-30/37
Ø 85
30
Ø 85
28-30/37
Ø 85
50
Ø 85
28-30/37
Ø 85
50
Ø 85
30
Ø 85
28-30/37
Ø 85
16