Fig. 3: Position of the siphon support

2.3 Installation instructions

Observe the details in the following dimensional diagram and installation diagram when installing the supply and
waste water lines. Install the system over the entire area and horizontally.
If you are working without the pump kit, mount the waste water line (DN 50 HT pipe) to the top left connection.
If you want to work with the pump kit, read chapter 5.1 Operation with immersion pump.
2.4 Connecting the pasting machine wash area, Item No. 61 20 20
In order to operate the WAMAB with the large wash area, the main tank must be connected with the sewage canal.
This must be carried out using the screw connection on the side and D=50 mm HT pipe (Figure 1).
For devices already installed, first undo the screw connection on the side of the WAMAB and disconnect it from the
sewage canal (Figure 1).
Fig.
1
Connecting to the sewage canal
Installation of the fitting kit, Item No. 61 20 05
Fig.
2
Fitting kit
Insert the adapter disc with hos nozzle as displayed in
figure 3.
Fig.
3
Inserting the adapter disc
Siphon support
45