8. TECHNICAL SPECIFICATIONS
Models
Outside dimensions
Inside dimensions
Weight
Power
Current
Voltage
Wires colours correspondence
The equipotential connection marked by this symbol
equipotential conductive connection of your installation by means of a minimum con-
duction of a 2.5 mm² section.
Energy consumption
Convection position
Rising up to 300°C
Maintenance 1 h at 300°C
Turbo Quartz position
Rising up to 300°C
Maintenance 1 h at 300°C
9. NORMS AND LEGALS DISPOSALS
The device is conform to :
IEC/EN 60335-1
IEC/EN 60335-2-36
IEC/EN 60335-2-42
EN 55014-1 + 55014-2
EN 61000-3-2 + 61000-3-3
.
FC 110 E
800 x 750 x 640 mm
670 x 450 x 350 mm
59 kg
6 kW
16 A/Phase
380-415 V 3 N~
Phase 1
Phase 2
Phase 3
Neutral
Earth
1.25 kw/h
2.50 kw/h
1.44 kw/h
2.40 kw/h
FC 110 EG
800 x 750 x 640 mm
670 x 450 x 350 mm
60 kg
6 kW
16 A/Phase
380-415 V 3 N~
Brown
Black
Grey
Blue
Yellow-Green
must be linked with the
28