FUSE CHECK/REPLACEMENT/RESET
1.
Drive the machine on a level ground and engage the
parking brake.
2.
Turn the ignition key (72) to "0".
3.
Open the hood (7).
4.
Disconnect the battery connector (46).
Lamellar fuse check/replacement
1.
Remove the fuse box cover (51).
2.
Check/replace the relevant fuse among the following (Fig.
19):
(A): F1 main fuse (key circuit) (15 A)
(B): F2 filter shaker motor fuse (25 A)
(C): F3 manual vacuum system fuse (40 A) (optional)
(D): F4 vacuum system motor fuse (30 A)
(E): F5 horn and pivoting light fuse (10 A)
(F): F6 working light fuse (10 A) (optional)
3.
Remove the electrical component box cover (55).
4.
Check/replace the following fuse (Fig. 20):
(A): FT drive system fuse (70 A)
Fuse check
1.
Check one of the following fuses (Fig. 19) for deactivation:
(G): FA main broom motor fuse (30 A)
(H): FB side broom motor fuse (10 A)
Reset any deactivated fuse, when the component that
caused deactivation has fully cooled down.
2.
Close the hood (7).
SAFETY FUNCTIONS
The machine is equipped with the following safety functions.
EMERGENCY PUSH-BUTTON
It is located in an easily accessible position (82). It has to be pressed in case of emergency, to stop all the machine functions.
DRIVER'S SEAT MICROSWITCH
It is located inside the driver's seat and it does not allow the machine drive system to operate if the operator is not seated on the
driver's seat.
1464026000(1)2009-04 A
USER MANUAL
G
A
B
C
D
E
Figure 19
Figure 20
FLOORTEC R 670 B
ENGLISH
H
F
P100348
A
P100349
23