1.
Place the pusher tool on the joint to be pressed in accordance with information from the
EN
system manufacturer.
2.
Press the start button and hold it until the pressing process is complete.
9.3
Meaning of the LED display
LED display
All LEDs off.
Green LED (2) lights up.
Green LED (2) flashes.
Green LEDs (4)
Red LED (3) flashes.
Red LED (3) lights up.
Red and green LED (2)
flash alternately.
CAUTION!
Danger of crushing by moving parts
Fingers risk being crushed.
Therefore:
– Keep all body parts and foreign objects away from the operating zone.
Information!
The pusher tool must be held in the aligned position during the entire pressing
operation.
Status/cause
The device is switched off.
Ready for operation.
Insufficient battery charge.
Battery charge display
Device not within the
temperature range.
Device fault.
Service interval reached.
Measure
Briefly press the start button (1)
(see section 7.4).
Charge or replace battery.
The device only works within a
temperature range from -10 to +50
°C. If the red LED is flashing, the
device must be moved into a
warmer or colder area. The device
can be warmed to operating
temperature by means of dry runs.
Press the start button (1). If this is
unsuccessful, the press device is
defective.
Send the device to a specialist
workshop.
NOTE
The pressing operation may not
have been completed; please
check and repeat if required.
Take the press device to be
serviced.