Télécharger Imprimer la page

Pontec PondoSolar 150 Notice D'emploi page 7

Masquer les pouces Voir aussi pour PondoSolar 150:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Scope of delivery
5 A
Quantity
1
1
2
1
3
4
4
1
5
4
6
1
7
1
Intended use
PondoSolar 150, referred to as "unit", may only be used as specified in the following:
· For creating a water fountain in a pond.
· For operation with clean water.
· Operate in accordance with instructions.
· Operation under observance of the permissible water quality. (® Water quality)
The following restrictions apply to the unit:
· Never use the unit with fluids other than water.
· Never run the unit without water.
· Do not use for commercial or industrial purposes.
· Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
· Do not connect to the domestic water supply.
Installation and connection
How to proceed:
5 B
1. Assemble the nozzle unit and fit onto the pump.
– Adapt the number of nozzle extensions used to the depth of the pond.
2. Connect the connection cable to the solar module.
– Push the plug completely into the socket (up to the stop) to ensure that the connection is watertight.
– Switching on: Connect the pump to the solar module.
– Switching off: Disconnect the solar module from the pump.
3. Assemble the ground stake set and attach it to the solar module.
– Ensure that the connection cable is routed downwards.
4. Fix the pump underwater to a smooth, clean surface using the suction cups.
5. Install the solar module so that it is exposed to direct sunlight.
– Recommendation: Align the solar module to the sun to ensure maximum energy yield.
Remedy of faults
Malfunction
Pump does not start.
Insufficient or no pump delivery.
Description
Filter housing
Pump with outlet and 5 m connection cable
Nozzle extension
Nozzle holder
Nozzle attachment
Solar module
Ground stake set
Cause
No connection to the solar module.
The solar module is soiled.
The impeller unit is blocked
The filter is clogged.
The nozzle unit is clogged.
The impeller unit is worn.
Insufficient sunlight
Remedy
Connect the pump to the solar module.
Correctly insert the connection cable.
Clean
Clean
Open the pump, remove and clean the filter.
Remove and clean the nozzle unit.
Replace
Direct sunlight
- EN -
7

Publicité

loading