Télécharger Imprimer la page

MSW Motor Technics MSW-PSM 800 Manuel D'utilisation page 5

Publicité

EN
20.
Check damaged parts. Before further use of the tool, any parts of the casing or other parts that are damaged should
be carefully checked to determine that they will operate properly and perform their intended function. Check for
alignment of moving parts, mounting, and any other conditions that may affect the machine's operation. A part of the
casing or other part that is damaged should be properly repaired or replaced by an authorized service centre unless
otherwise indicated elsewhere in this instruction manual. Defective switches should be replaced by an authorized
service centre. Do not use the tool if the switch does not turn it on and off.
21.
Do not use power tools for applications other than those specified in the instruction (other than those for which it
was designed).
22.
To ensure the designed operational integrity of power tools, do not remove installed parts of the casing or screws.
23.
Do not touch movable parts or accessories unless the power source has been disconnected.
24.
Use your tool at lower input load than specified on the nameplate to increase working efficiency and decrease wear
out.
25.
Do not wipe plastic parts with solvent. Solvents such as gasoline, thinner, benzene, alcohol, ammonia and oil may
damage and crack plastic parts. Do not wipe them with such solvents. Wipe plastic parts with a soft cloth lightly
dampened with soapy water.
26.
Consult an authorized service agent in the event of power tool failure.
27.
Use only original replacement parts.
28.
This tool should only be disassembled for replacement of carbon brushes.
29.
When using the machine pay special attention to a recoil, which is a sudden reaction of the machine to the rotating
disc blocking. As a consequence of blocking of the rotating tool, the machine tugs in a direction opposite to the disc
rotation direction. The recoil is a consequence of inappropriate use of the machine.
30.
The power cord should be kept away from the rotating parts of the machine.
31.
Clean the machine's ventilation slots regularly.
III. PRECAUTIONS ON USING THE MACHINE
1.
Wear protective glasses to protect your eyes.
2.
Use earplugs to keep your ears noise-free while working.
3.
Use dust masks.
4.
Pay attention to the correct adjustment of the grip.
5.
The tool becomes very hot during operation.
6.
Safe operation depends on one's work posture.
7.
Wear protective shoes to protect your feet. Wear protective gloves.
8.
To avoid injury from accidental starting, always remove the plug from the electrical socket before installing or remo-
ving the disc, plate, or other removable accessories.
9.
The machine should always be turned on/turned off at the lowest speed range (1).
Failure to follow safety recommendations and instructions may result in serious injuries or death!
IV. TECHNICAL SPECIFICATIONS
Product name
Dual Action Polisher
Model
MSW-PSM 800
Rated voltage/frequency
230V±10%/50Hz
Rated power
800W
Sound power level L
95dB(A), Unsicherheit K=3dB(A)
wA
Sound pressure level L
84dB(A), Unsicherheit K=3dB(A)
pA
Vibration emission value
9,82m/s2, Unsicherheit K-1,5 m/s2
Rotational speed
1800-7000obr/min
Max. disc diameter
5" (ø125)
Dimensions (L x W x H)
350x122x150(mm)
Weight
2,8kg
8
Polisher
MSW-PM 800
230V±10%/50Hz
800W
109dB(A), Unsicherheit K=3dB(A)
98dB(A), Unsicherheit K=3dB(A)
7,28m/s2, Unsicherheit K-1,5 m/s2
700-3000obr/min
5" (ø125)
360x124x124(mm)
2,7kg
Rev. 17.02.2022
V. BEFORE FIRST USE
Upon receipt of the goods, check the packaging for integrity and open it. If the packaging is damaged, please contact your
transport company and distributor within 3 days and document the damages as detailed as possible. Do not turn the
package upside down! When transporting the package, please ensure that it is kept horizontal and stable. The various items
used for packaging (cardboard, plastic straps, polyurethane foam) should be conserved, so that the machine can be sent
back to the service centre in the best condition possible in the case of any problems!
VI. OVERVIEW
MSW-PSM 800
1
5
3
4
MSW-PSM 800 RPM range:
Adjustment range 1
2
RPM range
1000
1700
MSW-PM 800
1
6
3
2
6
7
MSW-PM 800 RPM range:
Adjustment range 1
2
RPM range
700
1100
VII. PRINCIPLES OF OPERATION
1. Before first use.
Make sure that the supply voltage conforms to the voltage indicated on the machine's name plate.
Before each connection of the power supply to the machine check the switch position; the switch must always be in
the "off" ("0") position. If the switch is in the "on" ("I") position, the machine will start unintentionally upon energising
which may lead to an accident!
Check the condition of the power cord and plug. If the power cord or plug needs replacement, seek assistance from a
qualified service organisation.
Rev. 17.02.2022
EN
2
1.
On/off switch
2.
Speed regulator
3.
Ventilation
4.
Disc
5.
Handle mounting location
3
4
5
6
2300
3000
3500
4000
1.
Handle
4
2.
Spindle lock
3.
On/off switch
5
4.
Speed regulator
5.
Ventilation
6.
Handle mounting location
7.
Disc
3
4
5
6
1600
2100
2600
3000
9

Publicité

loading

Ce manuel est également adapté pour:

Msw-pm 800