Optional Accessories; Maintenance; Disposal; What To Do If - Nice mindyA60 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
Switch 10:
On
This function checks photocell efficiency at the beginning of each manoeuvre. See the PHOTOTEST chapter.
Switch 11:
On
In this mode, the clean contact of the courtesy light output will remain closed for 1 sec. at the starting of each opening or closing manoeuvre,
thus enabling a command impulse to be sent to an external timer.
Switch 12:
On
In this mode, the CLOSE input loses it basic function and becomes a Pedestrian Step-by-Step input that allows the gate leaf controlled by
motor 2 to be opened for pedestrian access.
The Pedestrian opening cycle can only be activated when the gate is closed, while if the gate is moving or open the impulse has no effect on
the input.

7) Optional accessories

RADIO card
The control unit features a connector for plugging in an SM radio card , which activates the "Step-by-Step" and "Stop" inputs and allows the
control unit to be remote-controlled through a transmitter.
output 1
output 2
output 3
output 4

8) Maintenance

The control unit, being electronic, needs no special maintenance. However, periodically make sure (at least once every six months) that the
device adjusting the motor force is in perfect working order; adjust with the trimmer if necessary. Carry out the entire testing process again to
make sure that the safety devices (photocells, pneumatic edges, etc.) and the flashing light are in perfect working order.

9) Disposal

This product is made from various kinds of material, some of which can be recycled.
Make sure you recycle or dispose of the product in compliance with laws and regulations locally in force.
Some electric components may contain polluting substances; do not dump them.

10) What to do if ...

This section will help fitters solve some of the most common problems that may arise during installation.
No LED is on:
Check whether the control unit is powered (make sure that mains voltage is present at terminals 1-3 and a voltage of approx. 24Vac at
terminals 17-18).
Check the 2 mains fuses have not blown; if none of the LED's comes on a serious fault has probably occurred and the control unit should
therefore be replaced.
The OK LED flashes regularly but the INPUT LED's do not reflect the status of the corresponding inputs
Carefully check the connections on input terminals 20÷27
The manoeuvre does not start
Check that the LED's for the STOP, PHOTO and PHOTO1 safety devices are on, and that the LED for the activated command (STEP-
BY-STEP, OPEN or CLOSE) remains on for the whole duration of the command.
The gate changes direction during a manoeuvre
Reversal of movement is caused by:
Triggering of the photocells (PHOTO and PHOTO1 ); in this case, check the photocell connections and, if necessary, check the input LED's.
= Phototest
= Courtesy light in impulse mode
= CLOSE becomes OPEN for Pedestrians
STEP-BY-STEP
STOP
not used
not used
GB
13

Publicité

Table des Matières
loading

Table des Matières