EN
Problem
The drill does not gener-
ate much torque or revolve
quickly even though it is
fully charged.
Model No: EY3732
Problem
The LED lights do not
come on when the switch is
flipped, or they turn off after
a few minutes.
None of the LED lights
come on when the switch is
flipped, or alternatively, one
or more of the lights turn off
after a few minutes.
Stop using the product immediately in the following cases:
Model No: EY0L32
●The charging lamp (green) flickers on and off immediately after charging.
● The battery pack has not finished charging 70 minutes or more after the battery pack
was inserted into the charger and the green light came on.
EY7530_7430_3732_0L32_02(Eng).indd
Cause
A battery pack that had
cooled to below -20°C was
used.
Cause
Battery pack is not charged.
Something is stuck between
the unit and the battery pack
at the contact points.
The battery pack has
reached the end of its
service life.
An incompatible battery
pack is being used.
The unit is broken.
- 24 -
24
Remedy
Charge again. Use only
after charging is complete.
Remedy
Please charge the battery
pack.
Remove the obstruction.
Replace the battery pack.
Replace the incompatible
battery pack with one that is
compatible.
Stop using it immediately
and return it to the retailer.