4.3 Rinsing the injector
IMPORTANT: The injector must
always be rinsed thoroughly
through after use. Remains of
topax detergent or topax disin-
fectants may clog the injector so
it needs to be rinsed or repla-
ced. The following procedure will
remove topax detergent and/or
remains of topax disinfectants from
the injector.
1. Remove User Pack, if any.
2. Turn handle on the right side of
the machine into foam po si ti on.
3. Hold the rinsing bottle with clean
water tightly against the suction
opening (with User Pack) or
against the hose (without User
Pack).
Alternatively, you can place a
User Pack with clean water in
the holder or - without User
Pack - place the hose in a
bucket of clean water.
4. Activate the spray handle until
clean water comes out of the
nozzle (approx. 30 seconds).
N.B. This procedure should be fol-
lowed both on the topax de ter gent
and the topax disinfectant side (if
this is installed).
5. Service
Only let authorized and qualifi ed
personnel carry out service.
Warning: The main station system
must only be serviced when there
is no voltage or pres su re on the
system:
1. Turn off the main switch.
2. Close the ball valve on the inlet
side.
3. Open a water tap.
5.1 Components
5.1.1
Pump/motor
Pump/motor is maintenance-free.
See section 2.2.
5.1.2
Control system
Maintenance-free.
If defective: Call service technician.
5.1.3
Flow switch
Maintenance-free. See section 3
and Fig. 13.
If defective, replace the fl ow switch.
Adjustment
1. Press "0" on the control panel
to stop the system.
2. Turn the switch on the right side
of the main station into foam
6. Turn the brass screw at the
bottom of the hole until 2 green
diodes light up.
7. Close the water outlet again and
check that the red diode lights
up.
8. Remount the nylon screw.
5.1.4
Non-return valve
Maintenance-free.
If defective, replace the non-return
valve.
17