18
7. Tighten TANK SUPPORT equally with FLANGE
NUTs. Then lock with HEX, NUT. (Fig.33 (4) (5))
[Tightening torque: 17.6 to 19.6 N-m (1.8 to 2.0 kgf-m)]
(1) TANK BASE <20>
(2) FLANGE NUTS <27> x 4
(3) HEX. NUTS <26> x 4
(4) FLANGE NUTS <27> x 2
(5) HEX. NUTS <26> x 2
8. Set TANK STAY and tighten BOLTs (WITH LOCK
AND PLAIN WASHER) firmly. (Fig.32)
[Tightening torque: 23.5 to 27.5 N-m (2.4 to 2.8 kgf-m)]
9. Connect
HYDRAULIC
HYDRAULIC RETURN HOSE to AUXILIARY TANK
ASSY with HOSE CLAMPs respectively. (Fig.31)
[Tightening torque: 4.0 to 5.0 N-m (0.41 to 0.51 kgf-m)]
10. Install TEMP. SWITCH to FILTER BASE with SEAL
WASHER. (Fig.31 (12))
[Tightening torque: 2.9 to 3.9 N-m (0.30 to 0.40 kgf-m)]
SUCTION
HOSE
and
[8] Assembly of BREATHER HOSE ASSY
1. Insert BREATHER (#10978) into BREATHER HOSE,
then clamp them with HOSE CLAMPS. (Fig.34)
(1) BREATHER (#10978) <39>
(2) BREATHER HOSE <38>
(3) HOSE CLAMP <40> x 2
2. Connect BREATHER HOSE ASSY. (Fig.35 (1)) to
BREATHER PIPE (3) with HOSE CLAMP. (Set HOSE
CLAMP 5 mm from the end)
3. Clamp hoses to INTAKE AIR PIPE, with TIE CABLE
(LONG).
(1) BREATHER HOSE ASSY <38 to 40>
(2) HOSE CLAMP <40>
(3) BREATHER PIPE
(4) TIE CABLE (LONG) <63>
(5) INTAKE AIR PIPE
(6) TANK STAY <23>