Installation
7.2.7
Installing the air outlet unit
a
Caution – risk of damage
When attaching the suction head of the air outlet unit, make sure that the
screws are tightened with due care, to avoid overwinding. Jerking and
dragging on the suction head must be avoided, as it could come loose
from the intake hose.
➤ Insert both plugs of the connection line (ribbon cable) between the
➤ Connect the suction head to the air outlet unit. For this use the 6 coun-
➤ Attach the air outlet unit to the fastening frame with the 4 self-tapping
7.3
Configuration of system software
Before you first start up the system, adapt the controls according to the
installation conditions. This must be done by the person installing the sys-
tem.
In configuration mode, the following system software parameters must be
set:
Menu
30
system and the air outlet unit into the socket on the control board (see
arrow, fig. a, page 5).
tersunk screws provided (3.5 x 13) (fig. b, page 5).
screws (4.8 x 25) (fig. c, page 6). At this point make sure that the air
outlet unit is fastened securely to the roof.
Parameter
level
1
Set temperature
2
AC-DC switching The system software is modified for oper-
3
Operating mode
4
Space factor
5
Default settings
Explanation
The system starts with the temperature
defined here.
ation with the DC expansion kit.
The system starts with the operating
mode defined here.
The space factor defined here controls
the activation of the fan and compressor
in automatic mode.
Parameters 1-4 can be returned to the
default settings.
Dometic CA1000
Default
setting
20 °C
1 = AC
0 =
Automatic
mode
5