Module Modbus RTU
Description
No meaningful ultrasonic received signal
-> Air in the measuring path
Battery almost flat
Forward and return sensor reversed
Wrong direction of flow in volume measuring component
-> Flow rate = 0
Leakage detected
Communication not possible (to frequent data update
rate from heat mater)
-> Set higher value in 41002 Modbus Register
11 RESTORING DEFAULT SETTINGS
Press Status button for at least 15 seconds. Restore is confirmed by blinking of status LED (see Fig.
4). All configuration registers are restored to default value (chapter 6).
Default settings restore function is useful when currently configured communication settings of the
module are unknown.
If Modbus RTU Communication Module is connected to the meter during default settings restore, its
Modbus Slave ID will be automatically updated based on meter serial number (see chapter 6- automatic
slave ID).
12 RECYCLING
This product is electronic equipment and it must not be disposed of with other
domestic waste. It must be separately collected and recycled as waste electrical
and electronic equipment (WEEE) according to currently valid legislation.
The separate collection and recycling of waste equipment will help to conserve
natural resources and ensure that it is recycled in a manner that protects human
health and the environment.
Fig.4 – Process of restoring to default settings
Error Code value in
Error code of
30165 or 40165
the meter
Modbus Register
E-7
0x00 70
E-9
0x00 84
E-3
0x00 B0
E-6
0x00 D0
Leak error
0x00 F0
E-5
0x00 10
9
Priority
6
7
8
9
10
11