Module Modbus RTU
Designation
Tariff Volume 3 (Unit factor)
Tariff Volume 3 (Unit factor)
Tariff Volume 3 (Unit name)
Tariff Volume 3 (Unit ID)
Tariff Volume 3 (Float)
Tariff Energy 4
Tariff Energy 4 (Unit factor)
Tariff Energy 4 (Unit name)
Tariff Energy 4 (Unit ID)
Tariff Energy 4 (Float)
Tariff Volume 4
Tariff Volume 4 (Unit factor)
Tariff Volume 4 (Unit name)
Tariff Volume 4 (Unit ID)
Tariff Volume 4 (Float)
Pulse Input Volume 1
Pulse Input Volume 1 (Unit name)
Pulse Input Volume 1 (Unit ID)
Pulse Input Volume 1 (Float)
Pulse Input Volume 2
Pulse Input Volume 2 (Unit factor)
Pulse Input Volume 2 (Unit name)
Pulse Input Volume 2 (Unit ID)
Pulse Input Volume 2 (Float)
Error Code
Heat Meter Serial Number (Fixed)
Heat Meter Serial Number (ASCII)
Periodical Log 0 Date – Day
Periodical Log 0 Date – Month
Periodical Log 0 Date – Year
Periodical Log 0 Energy
Periodical Log 0 Energy (Unit factor)
Periodical Log 0 Energy (Unit name)
Periodical Log 0 Energy (Unit ID)
Periodical Log 0 Energy (Float)
Periodical Log 0 Volume
Periodical Log 0 Volume
(Unit factor)
Periodical Log 0 Volume (Unit name)
Periodical Log 0 Volume (Unit ID)
Periodical Log 0 Volume (Float)
Module Serial Number
Module Model Number
Module Firmware Version
Modbus
Modbus
Register
Register Type
30117 or 40117
Input or Holding
30117 or 40117
Input or Holding
30118 or 40118
Input or Holding
30122 or 40122
Input or Holding
30123 or 40123
Input or Holding
30125 or 40125
Input or Holding
30127 or 40127
Input or Holding
30128 or 40128
Input or Holding
30132 or 40132
Input or Holding
30133 or 40133
Input or Holding
30135 or 40135
Input or Holding
30137 or 40137
Input or Holding
30138 or 40138
Input or Holding
30142 or 40142
Input or Holding
30143 or 40143
Input or Holding
30145 or 40145
Input or Holding
30148 or 40148
Input or Holding
30152 or 40152
Input or Holding
30153 or 40153
Input or Holding
30155 or 40155
Input or Holding
30157 or 40157
Input or Holding
30158 or 40158
Input or Holding
30162 or 40162
Input or Holding
30163 or 40163
Input or Holding
30165 or 40165
Input or Holding
30166 or 40166
Input or Holding
30168 or 40168
Input or Holding
30172 or 40172
Input or Holding
30173 or 40173
Input or Holding
30174 or 40174
Input or Holding
30175 or 40175
Input or Holding
30177 or 40177
Input or Holding
30178 or 40178
Input or Holding
30182 or 40182
Input or Holding
30183 or 40183
Input or Holding
30185 or 40185
Input or Holding
30187 or 40187
Input or Holding
30188 or 40188
Input or Holding
30192 or 40192
Input or Holding
30193 or 40193
Input or Holding
32001
Input
32003
Input
32005
Input
7
Modbus
Data Value
Address
Range
116
UInt16
117
8 char ASCII
121
UInt16
122
IEEE 754
124
Int32
126
UInt16
127
8 char ASCII
131
UInt16
132
IEEE 754
134
Int32
136
UInt16
137
8 char ASCII
141
UInt16
142
IEEE 754
144
Int32
146
UInt16
147
8 char ASCII
151
UInt16
152
IEEE 754
154
Int32
156
UInt16
157
8 char ASCII
161
UInt16
162
IEEE 754
164
Hex
165
UInt32
167
8 char ASCII
171
UInt16
172
UInt16
173
UInt16
174
Int32
176
UInt16
177
8 char ASCII
181
UInt16
182
IEEE 754
184
Int32
186
UInt16
187
8 char ASCII
191
UInt16
192
IEEE 754
2000
UInt32
2002
Unit32
2004
Unit16
04/2019