Télécharger Imprimer la page

Westfire WF35 Notice D'installation Et D'utilisation page 11

Publicité

UK
WESTFIRE · WF35
Westfire Insulated chambers
The WESTFIRE UNIQ 35 stove is lined with vermiculite heat deflection panels and baffles, these panels are
designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove.
These baffles should not be removed other than for cleaning the stove. Any panels showing significant ware
should be replaced.
Connection to chimney
The WESTFIRE UNIQ 35 stoves are factory set up with a top flue outlet only; the flue outlet can be altered on the
inset model by removing the collar and rotating 180 degrees and re bolting. This will give a collar which is now at
a 45 degree angle. Care should be taken to ensure an airtight fit when refitting collar. This collar allows connec-
tion to either a stainless steel chimney liner or a prefabricated factory made insulated metal chimney. Westfire DO
NOT recommend installation of this appliance directly into a masonry chimney.
Commissioning and handover
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, a
small fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely
into the atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be
used on the stove and notify them to use only the recommended fuels for the stove. Advise the user what to do
should smoke or fumes be emitted from the stove. The customer should be warned to use a fireguard to BS 6539
in the presence of children, aged and/or infirm persons.
OPERATION & MANTANENCE OF YOUR APPLIANCE
Congratulations on your purchase of your new Uniq 35 new multi-fuel stove from Westfire ApS. The Westfire
UNIQ 35 is constructed in steel with a vermiculite insulated chamber.
Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and
to prevent any problems. Please note that "all local regulations, including those referring to national and Euro-
pean Standards, need to be complied with when installing this appliance".
Warning
CO Alarm: Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds
unexpectedly, follow the instructions given under "Warning Note" above . Use a fireguard in the presence of
children, and old and/or infirm people. The fireguard should be manufactured in accordance with BS 8423:2002,
Fireguards for use with solid fuel appliances.
11

Publicité

loading