2.1 ELECTRIC INSTALLATION
WARNING!
THE ELECTRICAL INSTALLATION MUST BE MADE BY A
LICENSED ELECTRICIAN.
Check that the electrical specifications of the power
source are the same of the machine. The machine uses
0.75 kW.
Electric specifications are clearly marked on a label at
the end of the electric cord.
If the plug is provided disregard this paragraph.
Connect the electric cord of the machine with an
approved plug. The ground cable (green and yellow)
must be properly connected.
WARNING!
FAILURE TO PROVIDE PROPER ELECTRICAL SUPPLY AND
GROUNDING WILL CREATE A SHOCK HAZARD TO THE
OPERATOR.
8
2.2 AIR INSTALLATION
WARNING!
THE AIR INSTALLATION MUST BE MADE ONLY BY LICENSED
PERSONNEL.
WARNING!
EXCESSIVE AIR PRESSURE CAN SERIOUSLY INJURE
PERSONNEL AND DAMAGE THE MACHINE.
Ensure that the line pressure is within the limits required
by the machine. If the pressure exceeds 170 psi (12 bar)
it is mandatory to install a pressure regulator before the
air inlet of the machine.
If the air pressure is lower than the minimum required of
110 psi (8 bar) the clamping power of the turntable and
the bead breaker power may be insufficient for certain
tires.
It is suggested that the air supply be equipped with a
water separator and air lubricator.
After ensuring all the above proceed as follows:
A. Connect the machine to the air supply with a rubber
hose (rated for the pressure) with an internal diameter
of no less than 1/2" (12.5mm).
540
WARNING!
BEFORE CONNECTING THE MACHINE TO THE AIR SUPPLY
BE SURE ALL PERSONNEL ARE CLEAR OF THE MACHINE
AND THAT NOTHING IS LEFT ON THE TURNTABLE AREA
(TOOLS)
B. Should you install any optional accessories, please
refer to the relevant instructions.
C. Should an air lubricator be installed, ensure the
functional ability of the unit.
Follow instructions of maintenance @ 7.0.(I.)
Operator's Manual
ACCU 3602