Connection Diagram; Terminal Assignment For Plug 5 Pole; Commissioning Certificate - Olsberg Levana Aqua Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection diagram

1) 78/4543.1481
Safety
temperature
limiter
STB
Netz
Power
supply
Zündung
Ignition
Rost (Zubehör)
Grate (accessory)
Pumpe (Kessel)
Pump (boiler)
Zuluftklappe
(Zubehör)
Supply air damper
(accessory)
Saugzug
Induced draught
Konvektionsluft-
gebläse (Zubehör)
Convection air blower
(accessory)
Schnecke
Auger

Terminal assignment for plug 5 pole

External room thermostat
Remove jumper if there
is an external contact
white
green
brown
Fig.8
Infrared remote control
70
Safety
Kippschalter (falls vorhanden)
temperature
STB
Tilt switch (if available)
limiter
100°C
Floating contact

Commissioning Certificate

Proper installation and commissioning of the appliance
is documented with the Commissioning Certificate.
Instruction provided by the specialist is the basic pre-
requisite for qualified operation of the appliance.
6-polig
6 pole
Einspielgerät
Import device
Erweiterung
Extension
Display
GSM
Datenübertragung
Data transmission
rot/red
+18V
Unterdruck
schwarz/black
GND
Underpressure
Signal
gelb/yellow
weiß/white
Flammtemperatur
NiCrNi
Flame temperature
grün/green
Pt1000
Raumtemperatur
Room temperature
Pt1000
Wassertemperatur (Ofen)
Water temperature (stove)
Pt1000
Puffer1 (Kessel)
Buffer1 (boiler)
Pt1000
Puffer2 (Kessel)
Buffer2 (boiler)
Pelletbehälterdeckel
Pellet tank cover
Rost (Zubehör)
Grate (accessory)
Zuluftklappe (Zubehör)
Supply air damper
(accessory)
Externer Raumthermostat
External room thermostat
rot/red
+5V
Hallgeber
schwarz/black
GND
Hall sensor
Signal
weiß/white
Infrarot-
weiß/white
Fern-
grün/green
bedienung
braun/brown
(Zubehör)
Infrared remote control
(accessory)

Publicité

Table des Matières
loading

Table des Matières