Display
settings
timer
date & time
language
convect.
n.c.
frost pro
---
night set
---
max. power
5
standby
on
temp drop
2°C
temp. off
1°C
delay
---
bufferON 50°C
bufferOFF 70°C
GSM mod. n.c.
52
Action
Description
Settings
The following settings can be selected with ↓ or ↑
and called up with (ENTER):
● timer
Timers can be stored at which the appliance will
be switched on or off automatically.
● date & time
Through the "date & time" setting the change be-
tween daylight saving time and normal time is ex-
ecuted.
● language
The following languages can be selected:
Deutsch, English, Français
● convection
For Levana Aqua no convection air blower is pro-
vided.
● frost protection
The frost protection temperature can be set at 5°C
to 10°C or "---".
Factory setting: ---
● night set
(only for "automatic" mode)
or
The night set temperature can be set at 5°C to
20°C or "---".
Factory setting: ---
● max. power
(only for "automatic" mode)
The max. power level can be set on 1 to 5.
Factory setting: 5
● standby
(only for "automatic" mode)
Standby operation can be switched on or off.
Factory setting: on
● temperature drop
(only for "automatic" mode)
The temperature drop for starting the appliance
can be set from 1°C to 6°C.
Factory setting: 2°C
● temperature off
(only for "automatic" mode)
The switch off hysteresis of the appliance can be
set from 1°C to 3°C.
Factory setting: 1°C
● delay
If an external room thermostat is connected the
delay can be set from 1 to 9 minutes or "---".