Olsberg Levana Aqua Manuel D'utilisation page 53

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Display
information
Ver.
1.00.35 A8
service
2000h
op.hours
0h
ext.req.
on
GSM mod.
n.c.
error messages
operating data
service level
Action
Description
● buffer ON
The switchON point can be set depending on the
buffer temperature between 35°C and 65°C.
Factory setting: 50°C
● buffer OFF
The switchOFF point can be set depending on the
buffer temperature between 40°C and 70°C.
Factory setting: 70°C
● GSM module
The GSM module is an accessory (see chapter
"Accessories").
Information
The following information can be selected with ↓ or ↑
and called up with (ENTER):
● Version
The software version will be displayed.
● service
Display for the next service according to operat-
ing hours.
● operating hours
The operating hours since commissioning will be
displayed.
● extern request (ext.req.)
or
The system shows whether an external compo-
nent (accessory e.g. room thermostat) switches
the appliance on or off.
● GSM module
The system shows whether a GSM module (ac-
cessory) is installed.
● error messages
The last 5 error messages are displayed.
● operating data
Current display for: Flame temperature, speed
of the induced draught fan, heat power level,
underpressure
● service level
The service level is a password protected level for
the service technician.
53

Publicité

Table des Matières
loading

Table des Matières