Information "operating hours"
Display
information
Ver. 1.00.35 A8
service
1988h
op.hours
12h
Information "extern request"
Display
information
service
1988h
op. hours
12h
ext.req.
on
Information "GSM module"
Display
information
op. hours
12h
ext.req.
on
GSM mod.
n.c.
62
Action
Description
The operating hours (op.hours) since commission-
ing, e.g. 12 h are shown.
Action
Description
As "extern request" (ext.req.) an external room ther-
mostat can be connected. Because the internal room
temperature sensor is also still connected the signal
that first switches will be taken for control. If the tar-
get temperature is specified with the external room
thermostat, the adjustable room temperature must
be set to the maximum value (40°C) in "automatic"
operating status.
With the aid of the display you can check wheth-
er the external room thermostat has been correct-
ly connected and is taking over control of the ap-
pliance. When adjusting the room temperature on
the room thermostat above or below the actual room
temperature, "on" or "off" must be shown in the dis-
play.
If an external component is not connected, the dis-
play always shows "on".
Action
Description
The actual status of the GSM module (accessory)
will be displayed:
- n.c.: The GSM module is not plugged in and is
- Init: The GSM module has been detected and is in-
- Ok: The GSM module is operational. SMS can be
- err: An error is present. Possible causes are con-
viewed as "not connected".
itialised.
received.
nection errors, SIM card not inserted or insuffi-
cient credit.