Heat Loss Charts
Idle
PLD 4.3
PLD 4.5
Load per Channel
1/8th Power
PLD 4.3
PLD 4.5
1/3rd Power
PLD 4.3
PLD 4.5
Full Power
PLD 4.3
PLD 4.5
EN
Idle
Thermal loss at idle or with very low signal level.
1/8 Power
Thermal loss at 1/8 of full power is measured with pink noise. It approximates operating with music or voice with light clipping and represents the
amplifier's typical "clean" maximum level, without audible clipping. Use these figures for typical maximum level operation.
1/3 Power
Thermal loss at 1/3 of full power is measured with pink noise. It approximates operating with music or voice with very heavy clipping and a very
compressed dynamic range.
Full Power
Thermal loss at full power is measured with a 1 kHz sine wave. However, it does not represent any real-world operating condition.
NOTE!:
TD-000368-00-A
BTU/hr
kcal/hr
225
57
286
72
8Ω
BTU/hr
kcal/hr
BTU/hr
684
172
811
204
983
248
881
222
2498
629
3116
785
Specifications are subject to change without notice.
4Ω
kcal/hr
BTU/hr
794
200
1040
1144
288
1124
1261
318
1869
1708
430
1737
2925
737
4198
5318
1340
4208
28
2Ω
kcal/hr
262
283
470.988
438
1058
1060

Publicité

loading

Ce manuel est également adapté pour:

Pld4.2Pld4.3Pld4.5