Set up the Inputs
NOTE!: Changes made to input levels are in real time.
HOME > INPUTS > INPUT SENS > ENTER
Step 1 — Select Input Sensitivity
F1: A B C D
Inputs > Input Sens
INPUT SENS
HOME > INPUTS > INPUT GAIN > ENTER
Step 2 — Set Input Gain
F1: A B C D
Inputs > Input Gain
INPUT GAIN
Set up the Outputs
NOTE!: Changes made to outputs are in real time.
Source Select
The PLD amplifiers are equipped with an internal router that allows you to select the input sources
for each of the four output channels.
• The default setting is Input 1 to Output A, 2 to B, 3 to C, and 4 to D.
Table 4
gives the possible input routings for a single output channel.
When you combine inputs, the input audio is summed equally to the output.
HOME > OUTPUTS > SOURCE SEL > ENTER
Step 1 — Select Input Source for each output channel
F1: A B C D
Outputs > Source Select
SOURCE SEL
Input Select
Input
1
+14 dBu
Press ENTER to confirm
Input
1
-11.8 dB
Press ENTER to confirm
Output
A
Input:
CH: 1
Press ENTER to confirm
19
Scroll to select (+14 or +4 dBu)
(The background turns to green.)
To confirm selection, press
To move to the next input, press
Repeat procedure for
remaining input channels.
Scroll to select (-100 thru 20 dB)
(0.1 dB increments)
To confirm selection, press
To move to the next input, press
Repeat procedure for
remaining input channels.
Input Routings
1
1+2
2
2+3
— Table 4 —
Scroll to select Input combination
(1), (1+2), (2), (2+3), (3), (3+4), or (4)
To confirm selection, press
To move to the next output, press
Repeat procedure for
remaining input channels.
ENTER
SEL
EN
ENTER
SEL
3
3+4
4
ENTER
SEL