Function and features
The encoder transforms rotational movement into pulse sequences.
These allow the measurement of linear distances and angular move-
ment as well as the determination of positions.
Electrical connection
Disconnect power from the installation before connecting or dis-
connecting cables or connectors!
Unused wires must be insulated to avoid short circuits and cross
faults.
Short-circuit protection
5 V TTL version:
10...30 V HTL version:
Standard wiring:
L+
L+ sensor
0V
0V sensor
A
A neg.
B
B neg.
0 index
0 index neg.
fault neg.
free
free
screen
6
outputs short-circuit protected against 0 V
outputs short-circuit protected against 0 V
and L+ for maximum 1 minute
Flange plug
5-pole
2
-
1
-
3
-
4
-
5
-
-
-
-
housing
ifm1000.xx
9
5
12
10
1
2
3
4
6
7
-
-
-
11
ifm1001.xx
12
2
10
11
5
6
8
1
3
4
7
9
-
housing