Télécharger Imprimer la page

Wolfcraft MASTER 750 ERGO Notice D'utilisation Originale page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
– Keep your work area clean and well lit. Untidy or dark work areas can lead
to accidents.
– Keep children and other persons at a safe distance when using the
working table. If you are distracted, you may lose control of the device.
– Remove the adjusting tools or spanners before switching on the power
tool. A tool or spanner left in a rotating part of the device can cause injury.
– Wear suitable clothing. Never wear loose clothing or jewellery. Keep
hair, clothing and gloves away from moving parts. Loose clothing, jew-
ellery or long hair can get caught in moving parts.
– Before starting work, check that the devices and tools are operational.
Never work with damaged or blunt tools.
– Disconnect the plug from the electric socket and/or remove the battery
from the power tool before adjusting the tool or changing accessories.
Accidents may occur if the power tool is started unintentionally.
– Avoid overloading the working table and never use it as a seat, ladder
or support. Placing excess weight on the working table or standing on it can
cause the centre of gravity of the table to shift, so that it tips over.
– Never reach into the saw area to remove loose fragments, chips or sim-
ilar materials from the area around the moving saw blade by hand!
There is risk of your hand or arm getting caught in the rotating tool, which
could cause severe injury.
– Before each sawing operation, make sure that there are no objects on
the worktop.
– Do not stop the saw blade by applying lateral pressure after switching
off the drive. This poses risk of damaging the saw blade or causing kickback.
– Only use tools for their actual intended purpose. Using power tools for ap-
plications other than the intended use can result in hazardous situations.
– Only use saw blades that are in perfect condition. Saw blades that are
blunt, defective or do not fit correctly can cause kickback or loss of control.
– Only use genuine wolfcraft spare parts.
– Additionally support protruding or large workpieces, to prevent risk of
tilting, and make sure that lateral clamping and machining of laterally
clamped workpieces does not result in the table becoming unbalanced.
When workpieces protrude beyond the table, the centre of gravity can shift
outward, which can cause damage to the workpiece or risk of injury from tilt-
ing.
– If you use mitre saws or drill stands on the working table, they have to
be firmly bolted to the table.
– Mount mitre saws or drill stands on the table only when the worktop is
in the 90° position.
– Do not use the working table with a clamped circular handsaw or in
combination with a cutting stand.
– Make sure that you do not apply excessive clamping pressure when
fastening fragile materials. There is risk of splintering!
– Remove all tools from the tool holders of the table before folding up the
table, so that there is no risk of the contained tools falling or damaging
the table.
– Take care not to pinch your hands when folding and unfolding the
table.
INTENDED USE
ERGO
The MASTER 750 
can be used for the following purposes:
– As a clamping and working table for machining workpieces (e.g. drilling,
sanding, etc.).
– For clamping workpieces between the table tops
– For clamping larger workpieces by means of plastic clamping jaws that have
been additionally mounted to the working table.
– For mounting mitre saws and drill stands. For this, the supplied fastening
bolts have to be used. • Observe the manufacturer's safety instructions for the
machines used, as well as the safety instructions for the working table.
FORESEEABLE MISUSE
Any use other than that described in the chapter on intended use is considered
reasonably foreseeable misuse, e.g.:
– Not observing the safety instructions for this product or the mounted tool.
– Mounting machines that apply lateral pressure to the working table.
– Using the table as work platform or seat.
– Applying a load of more than 125 kg.
– Clamping long workpieces with one end protruding without suitable support,
causing the centre of gravity to shift outward, which could result in the work-
ing table tilting over.
The manufacturer does not accept any liability for property damage or personal in-
jury resulting from reasonably foreseeable misuse or from failure to observe the op-
erating instructions.
PRODUCT OVERVIEW
PRODUCT DESCRIPTION
ERGO
The MASTER 750 
is a height-adjustable clamping and working table. It is suit-
able for use as a working table for machining workpieces (e.g. drilling, sanding,
etc.). With the working table, a variety workpieces can be clamped between the
table tops. The additional plastic clamping jaws permit larger workpieces to be
clamped. The height of the working table can be adjusted between
725 and 950 mm, in six steps. The tabletop can be variably inclined between
0° and max. 60°. The max. load is 125 kg. Mitre saws or drill stands may be
mounted on the working table using the fastening screws supplied; the technical
data has to be observed.
SCOPE OF DELIVERY
ERGO
Take the MASTER 750 
out of the cardboard box and check that the contents
are complete and all illustrated parts are included (Fig. 1).
TECHNICAL DATA
Dimensions when set up for use (width x
depth x height):
Dimensions when folded up (width x
depth x height):
Tilt of table surface:
Clamping area between table tops:
Clamping area between plastic clamping
jaws:
Clamping area for long objects that are
standing on the floor (Fig. 9.2):
Bore diameter of clamping holes:
Maximum load:
Weight:
ASSEMBLY
ASSEMBLY TOOL
The following assembly tools are required (not included in scope of supply):
Allen key:
Screwdriver:
A/F 4
PZ 3
ASSEMBLY
 CAUTION
Risk of crush injuries to fingers and hands during assembly
When moving parts are being mounted, there is risk of shear move-
ments, especially if the handle screws, which have a securing func-
tion, have not been mounted yet.
Pay attention to your hands and the selected holding positions dur-
ing assembly work. If necessary, ask a second person to assist you.
Place the lower section of the table on a flat, clean surface. Make sure that both
eccentric levers are pressed against the table legs, so that the telescopic adjust-
ment is fixed (Fig. 2.1).
Fold out the footpiece to the limit stop (Fig. 2.2) and place the worktop onto the
lower section. Make sure that the two pins on the right and left crossbars engage
in the slot on the telescopic adjustments of the base frame (Fig. 2.3). Tighten the
screw connections consisting of nut, washer, bearing bush and screw only to the
27
680 x 585 x 725 - 950 mm
680 x 190 x 970 mm
0° - 60°
130 mm
425 mm
50 - 110 mm
20.2 mm
125 kg
13.2 kg
Spanner:
A/F 10

Publicité

loading