6.3
Reading out measured values
Fig.107
Fig.108
7659613 - v02 - 08032017
Number of showers
4
5
6
7
Number of showers
5
6
7
8
9
6.3.1
CANCEL
CLOCK
Press 3s
for unlock
1. Increase the temperature value by pressing the up arrow key.
2. Decrease the temperature value by pressing the down arrow key.
Note
The factory setting is 55°C.
3. Exit this menu by waiting 10 seconds.
Settings table for the domestic hot water set point value ac
cording to the number of showers
ETWH 180 E
ECONOMY MODE =
ECONOMIC MODE
50
55
65
70
ETWH 230 E
ECONOMY MODE =
ECONOMIC MODE
50
55
60
65
70
Accessing the measured values
1. Unlock the control panel by pressing the CANCEL key for 3 sec
onds.
The locking indicator goes out.
2. Access the measured values by simultaneously pressing the
CLOCK and CANCEL keys for one second.
The appliance switches to maintenance and repair mode and the
consultation function can be accessed.
3. Press the arrows to show the measured values one by one (refer to
the table below).
4. Exit the measured values menu by waiting for 10 seconds.
en
6 Settings
ETWH 180 E
MODE OPT.BACKUP
= PEAK RATE/OFF-
PEAK RATE OPTIMI
SATION MODE
50
55
65
70
ETWH 230 E
MODE OPT.BACKUP
= PEAK RATE/OFF-
PEAK RATE OPTIMI
SATION MODE
50
55
60
65
70