Scope Of Delivery; Accessories (Optionally Available); Transport And Storage; Delivery - Wilo Actun OPTI-MS Série Notice De Montage Et De Mise En Service

Masquer les pouces Voir aussi pour Actun OPTI-MS Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
English
Type key
Example:
Wilo-Actun OPTI-MSH4.02-02
Actun
Submersible pump product range
OPTI
Series
Product type
MS
MS = Multipower Solar
Hydraulic version
H
H = progressive cavity pump (Helical Rotor)
I = stainless steel centrifugal pump (Inox)
4
Rated diameter in inches
02
Rated volume flow in m³/h
02
Number of steps
4.6.

Scope of delivery

• Submersible pump with flat cable (2.5 m)
• Sealing kit (casting resin cable connector with integrated water level sensor)
• Installation and operating instructions
• Hydraulics for individual installation (MSH only), with required thread adhesive
• For OPTI-MSI4.08... only: Adapter for discharge side, Rp 1½" to Rp 2"
4.7.

Accessories (optionally available)

• Cooling shroud
• Motor cable
• Signal cable
• Wilo-MS Control switchgear to operate one Wilo-Actun OPTI-MS with enhanced
functional scope
• All necessary electrical components to set up and operate a solar pump station
( photovoltaic cable, DC switch, male MC4 connector, etc.)
5.

Transport and storage

5.1.

Delivery

The shipment must be checked for defects immediately upon receipt (damage, com-
pleteness). Document any defects on the freight documentation! The transport compa-
ny or manufacturer must be notified of any identified defects on the day the shipment
was received. Claims reported after this date can no longer be invoked.
58
TRANSPORT AND STORAGE
WILO SE 11/2018 DIN A5

Publicité

Table des Matières
loading

Table des Matières