EN
USE AND MAINTENANCE MANUAL
IT
TYPE
nc
no
1
E00
E01/02 In the case of installation on pressure groups it allows individual definition of (E00),
2
d.05
d.1
3
ct0
ct9
4
5
dt0
dt9
Ar0
Ar1
6
d0.5
d1.5
7
P0.0
Px.x
8
9
t05
t99
c10
c30
10
dr0
dr1
11
SYNCHRONISATION
DIGIPRESS can be synchronised with another DIGIPRESS managing and protecting two pumps with cascade
operating with
alternate start sequence. Steps to follow to calibrate the synchronisation:
1. Set the pressure start and stop values identically on both the devices
For optimum synchronisation operation, the difference between the start and stop pressures must be at least 1 bar.
2. GO TO ADVANCED MENU: + +
- In point 2: select E01 in one unit (this will be the MASTER) and E02 for the other unit (this will be the SLAVE).
- In point 3: select identical differential parameter d.XX. It is the difference in pressure to start the main and auxiliary
pump; it is also the difference between the stop pressures of both pumps.
3. Press
repeatedly until exiting from the ADVANCED MENU
4. Press
to disable this unit. The screen will signal "OFF"
5. Press
one more time in both devices to enable synchronisation.
Note: After 10 cycles the unit configured as E01 will show pressure and the unit configured as E02 will show on the
screen the amps
16
SYSTEM REACTION
Allows selecting of the type of operation such as conventional pressure switch (nc
normally closed) or reverse pressure switch (no =normally open).
Master (E01) or Slave (E02)
It allows establishing of the differential between "Start pressure1" and "Start pressure2"
and/or "Stop pressure1" and "Stop pressure2".
It allows setting of a delay between 0 and 9 seconds upon start-up (It is not available in
the synchronised mode).
It allows setting of a delay between 0 and 9 seconds for shutdown
It allows activating of the system of automatic periodic resets ART (Ar1) or deactivating
of them (Ar0).
It allows setting of the minimum differential between "Start pressure" and "Stop pressu-
re" between the values of 0.5 bar (7.2 psi) and 1.5 bar (21.7 psi)
It allows setting of a minimum working pressure below which the device detects insuf-
ficient water. It is very useful in the basic DIGIPRESS model where there is no absorbed
current reading
Detection of insufficient water settable between 5 and 99 seconds
It allows establishing of a nominal current t% above which the device will activate the
overcurrent protection.
It allows activation of the self-learning of the absorbed current of the pump (dr1) or
deactivation of it (dr0). See chapter PRECISE DETECTION OF WATER INSUFFICIENCY.
DEFAULT
SETTING
nc
E00
d.05
ct0
dt0
Ar0
0,5 bar
7,0psi
0 bar
0 psi
20"
c20
dr0