Faults; Storage And Disposal; Storing The Device; Disposing Of The Device - Mennekes AMAXX Notice D'utilisation Et De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10. Faults

Warning
Risk of sustaining injury due the start-up of electri-
cal consumers
Electrical consumers, connected to the receptacle combi-
nation, may automatically start up upon reactivation of a
tripped protective device and cause injury.
• Activate a protective device only after all connected
consumers have been switched off or disconnected from
the receptacle combination.
Troubleshooting procedure
a) A residual-current protective device is being trig-
gered
• Visually check the receptacle combination and connected
electrical consumers for defects.
YES – there is a defect with one of the devices
• Have an electrician rectify the problem.
NO – there is no defect
• Switch on the residual-current protective device again.
The residual-current protective device is being triggered
again.
• Have an electrician rectify the problem.
b) An MCB or a D-type fuse-link is being triggered
• Visually check the receptacle combination and connected
electrical consumers for defects.
YES – there is a defect with one of the devices
• Have an electrician rectify the problem.
NO – there is no defect
• Check the connected loads of the connected electrical
consumers.
If the connected loads are correct:
• Switch on the MCB or the D-type fuse-link again.
The MCB or the D-type fuse-link is being triggered again.
• Have an electrician rectify the problem.

11. Storage and Disposal

11.1 Storing the device

For proper storage and to ensure trouble-free operation
of the device at a later time, the following points must be
observed:
• Clean the device before placing it into storage.
Ö
see page 17
• Pack the device in the original packaging or a suitable
cardboard box.
• Store the device in a dry and temperature-controlled room
at a temperature range 0 °C to 40 °C.

11.2 Disposing of the device

The device should be taken out of service, dismantled, and
properly disposed of at the end of its service life.
Only an electrician may take the device out of service and
dismantle it.
The applicable national statutory regulations and provisions
in the country of installation must also be complied for its
disposal.