Warning: certain extreme conditions can shorten the shelf life by a few days.
If in doubt, always remove the product for it to undergo either:
- a review
- destruction
The shelf life is not a substitute for periodic verification (minimum annually) which will assess the condition of the
product.
TO FIND YOUR LOCAL ANNUAL REVIEW CENTRE, VISIT WWW.DELTAPLUS.EU.
No modification or addition or repair of the PPE may be made without prior written consent from the manufacturer nor
without using their procedures.
Do not use beyond the area of use defined in the instructions for use.
The manufacturer cannot be held liable for any direct or indirect accident after a modification or use other than that
provided in this manual.
Do not use this equipment beyond its limits.
To ensure its working condition and therefore the safety of the user, the product should be checked systematically:
1 / visually inspect the following points:
- Condition of the metal parts: no wear, no deformation, no corrosion or oxidation
- General condition: look for any possible damage due to ultraviolet radiation and other climatic conditions
- Condition of the anchorage device: in accordance with installation instructions and recommendations
- That the general disposition of the work situation reduces the fall risk, the drop height and the pendulum movement in
the case of a fall.
- Correct operation and locking of connectors (EN362).
Specific conditions such as humidity, snow, ice, mud, dirt, paint, oil, glue, corrosion, wear of the strap or rope, etc.. can
significantly reduce the operation of the fall arrest device.
2 / in the following cases:
- Before and during use
- if in doubt
- in the case of contact with chemicals, solvents or fuels that could affect operation
- if it has been subjected to stress during a previous fall
- at least every twelve months by the manufacturer or a competent organization, mandated by them.
PERIODIC REVIEW of PPE:
An examination should be performed at least every twelve months by the manufacturer, or a competent person or a
competent organization, authorized by the manufacturer. This very important check is related to the maintenance and
efficacy of the PPE and hence the user's safety. A written document authorising reuse should be obtained during this
audit in order to reuse the PPE. This document will clarify that the user's safety is linked to maintaining the efficiency
and resistance of the equipment.
Replace the PPE if necessary.
In accordance with European regulations, the identification form must be completed prior to the first use of the product
and then updated and kept with the product as well as the manual by the user.
The legibility of the product labelling should be checked periodically.
STORAGE INSTRUCTIONS:
During transport and storage:
- keep the product in its packaging
- keep the product away from any sharp, abrasive, objects etc...
- keep the product away from sunlight, heat, flames, hot metal, oil, petroleum products, harsh chemicals, acids, dyes,
solvents, sharp edges and structures of small diameter. These items can affect the performance of the fall arrest device.
After use, store the product in its packaging in a cool, dry, ventilated area.
INSTRUCTIONS FOR CLEANING / MAINTENANCE:
For minor soiling, clean with a cotton cloth or a soft brush. Do not use abrasives. For heavy duty cleaning, a damp
cloth may be used and then left to dry naturally away from any direct heat source or heat, even for items that got
wet during use.
Do not use bleach, harsh detergents, solvents, gasoline or colouring, these substances can affect the performance of
product.
MARKING:
- Manufacturer identification: DELTAPLUS®
- Date (month / year) of manufacture, e.g. 08/2015
- The product reference TRAxx
- The batch number, e.g. 15.9999
- the indication of compliance with Directive 89/686/EEC (CE symbol)
- the number of the notified body involved in the regulation of equipment (0082 or 0333)
TRA20 TRA22 TRA30 TRA32 Anchorage device
UPDATE : 12.02.2016
13/88
B.P. 140 - ZAC de La Peyrolière
84405 APT CEDEX - FRANCE