English
15 Troubleshooting
15.1 Correcting faults on the wet/dry vacuum cleaner
Fault
The wet/dry vacuum
cleaner does not start
when switched on.
The wet/dry vacuum
cleaner switches off while
in operation.
The suction power is too
low.
36
Cause
The mains plug of the connecting cable or
extension cord is not plugged in.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
The fuse rating of the socket is too low.
The extension cord has an incorrect cross-
section.
The extension cord is too long.
The plug of the connecting cable or extension
cord has been pulled out of the socket.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
The fuse rating of the socket is too low.
The filter bag or the container is full.
The cartridge filter is dirty.
The container is full. The float is enabled.
Remedy
► Plug in the plug of the connecting cable.
► Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
► Switch off other loads connected to the same
circuit.
► Plug the connecting cable into a socket with
the correct fuse rating, @ 16.1.
► Use an extension cord with an adequate
cross-section, @ 16.2
► Use an extension cord with the correct
length, @ 16.2
► Insert the plug of the connecting cable or of
the extension cord.
► Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
► Switch off other loads connected to the same
circuit.
► Plug the connecting cable into a socket with
the correct fuse rating, @ 16.1.
► Replace filter bag or empty the container.
► Clean or replace the cartridge filter.
► Empty the container.
15 Troubleshooting
0458-889-9621-A