Troubleshooting; Correcting Faults On The Wet/Dry Vacuum Cleaner - Stihl SE 133 ME Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
English

16 Troubleshooting

16.1 Correcting faults on the wet/dry vacuum cleaner

Fault
The wet/dry vacuum
cleaner does not start
when switched on.
The wet/dry vacuum
cleaner switches off while
in operation.
Dust is escaping from the
wet/dry vacuum cleaner.
52
Cause
The plug of the connecting cord or extension
cord is not plugged in.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
The fuse rating of the socket is too low.
The extension cord has an incorrect cross-
section.
The extension cord is too long
The container is full. The float switch has
operated.
The float switch has operated.
The plug of the connecting cord or extension
cord has been pulled out of the socket.
The circuit-breaker (fuse) or the earth-leakage
circuit breaker has tripped. The circuit is
electrically overloaded or defective.
The fuse rating of the socket is too low.
The container is full. The float switch has
operated.
The cooling air filter is dirty. The wet/dry
vacuum cleaner is too warm.
The filter is damaged.
Remedy
► Plug in mains plug of connecting cord or
extension cord.
► Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
► Switch off other loads connected to the same
circuit.
► Plug the connecting cord into a socket with
the correct fuse rating, @ 17.1.
► Use an extension cord with a sufficient cross-
section. @ 17.2
► Use an extension cord with the correct
length. @ 17.2
► Empty the container.
► Check the float.
► Insert the plug of the connecting cord or of
the extension cord.
► Find and resolve the cause for the trip.
Engage circuit-breaker (fuse) or the earth-
leakage circuit breaker.
► Switch off other electrical consumers on the
same circuit.
► Plug the connecting cord into a socket with
the correct fuse rating, @ 17.
► Empty the container.
► Clean or replace the cooling air filter.
► Allow the wet/dry vacuum cleaner to cool for
5 minutes.
► Replace the filter.
16 Troubleshooting
0458-660-9621-A

Publicité

Table des Matières
loading

Table des Matières