6.3 Place of installation
For the minimum distances that must be re-
spected when positioning the appliance with
respect to flammable materials and objects, refer
to the instructions in Fig. 12.
Y2
X1
Model
X1
X2
LEA US
800
100
LEA
800
100
Floors made of flammable material such as wood,
parquet, linoleum, laminate or floors covered
with carpets must be protected by a fireproof
base under the appliance that also protects the
front during cleaning from any falling burning
residues.
The manufacturer declines all responsibility for
any variations in the characteristics of the mate-
rial constituting the floor under the protection.
Set up an accessible technical space
for any maintenance work.
Remember to respect the minimum distance
from flammable materials (X), shown on the
identification plate of the pipes used to make the
chimney (Fig. 13 - Fig. 14).
Pi = Flammable wall
Pp = Floor protection
58
Z
X2
Y1
Fig. 12
Y1
Y2
Z
200
200
600
mm
200
200
600
mm
LEA US
Pi
X1
LEA
Pi
X1
Pp
Set up the electricity supply line to arrive near the
appliance for the connection of the power cable.
Pi
X
Pp
Fig. 13
Pi
X
Fig. 14
004776771 - 29/10/2021