CAUTION:
Be absolutely sure to insert the nail of the carbon
brush into the contact portion outside the brush tube.
(You can insert whichever one of the two nails
provided).
Caution must be exercised since any error in this
operation can result in the deformed nail of the carbon
brush and may cause motor trouble at an early stage.
6. Cleaning on the outside
When the driver drill is stained, wipe with a soft dry
cloth or a cloth moistened with soapy water. Do not
use chloric solvents, gasoline or paint thinner, for
they melt plastics.
7. Storage
Store the driver drill in a place in which the tempera
ture is less than 40°C and out of reach of children.
8. Service parts list
CAUTION:
Repair, modification and inspection of Hitachi Power
Tools must be carried out by a Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATIONS:
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts may be changed without
prior notice.
GUARANTEE
We guarantee Hitachi Power Tools in accordance with
statutory/country specific regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a Hitachi Authorized Service Center.
NOTE:
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
13
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 81 dB (A)
Measured A-weighted sound pressure level: 70 dB (A)
Uncertainty Kp
: 3 dB (A).
A
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN60745.
Drilling into metal:
Vibration emission value
2
Uncertainty K = 1.5 m/s
WARNING
The vibration emission value during actual use of the
power tool can differ from the declared value
depending on the ways in which the tool is used.
To identify the safety measures to protect the operator
that are based on an estimation of exposure in the
actual conditions of use (taking account of all parts of
the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to
the trigger time).
a
h, D = 1.5 m/s
2