POWER CORD REPLACEMENT
If the supply cord needs replacing, the task must be carried
out by the manufacturer, the manufacturer's agent, or an
authorised service centre in order to avoid a safety hazard.
TROUBLESHOOTING
The following chart contains information designed to assist in diagnosing and resolving router problems.
SYMPTOM
Router will not operate
Router runs slowly
Makes an unusual sound
Excessive vibration
Heavy sparking occurs inside
motor housing
Micro adjuster "clicks"
Plunge lock lever not locking
GB
Shutter on power switch not
releasing
Can't plunge to collet lock
position
Service / Troubleshooting
10
POSSIBLE CAUSE
• No supply of power
• Brushes worn or sticking
• Switch is faulty
• M otor components faulty or short
circuited
• Blunt or damaged cutter
• Variable speed set low
• Motor is overloaded
• Mechanical obstruction
• Armature has shorted sections
• Bent cutter shank
• Brushes not moving freely
• A rmature short circuited or open
circuited
• Commutator dirty
• Plunge lock engaged
• P lunge selector button is engaged
• R eached end of adjustment
range.
• Plunge lock lever not
correctly positioned
• R outer is plunged to full depth - in
collet lock position
• Power switch "On"
REMEDY
• Check that power is available at source
• D isconnect power, open brush caps and
ensure brushes move freely in the holders.
Check whether the brushes require
replacing - see Page 9
• Go to www.tritontools.com for your nearest
Triton Approved Service Agent
• Go to www.tritontools.com for your nearest
Triton Approved Service Agent
• Re-sharpen or replace cutter
• Increase variable speed setting
• Reduce pushing force on router
• Go to www.tritontools.com for your nearest
Triton Approved Service Agent
• Go to www.tritontools.com for your nearest
Triton Approved Service Agent
• Replace cutter
• D isconnect power, remove brushes, clean
or replace
• Go to www.tritontools.com for your nearest
Triton Approved Service Agent
• Go to www.tritontools.com for your nearest
Triton Approved Service Agent
• Release plunge lock lever
• d isengage the plunge selector button. Refer
to 'Handle Winder Plunge'
• Reset the router
• R eposition plunge lock lever as described in
'Free Plunge'
• Reduce plunge depth
• Switch power 'Off'