1. Layout (Fig. 1)
1 Tank cover
2 Carry handle
3 Safety tripping element
4 Choke lever
5 ON/OFF switch
6 230 V ~ socket
7 Reversing starter
8 Petrol cock
2. Items supplied
Generator
3. Proper use
The device is designed for applications operated with
a 230 V alternating current source. Be sure to
observe the restrictions in the safety instructions. The
generator is intended to provide electric tools and
light sources with electricity.
When using the device with household appliances,
please check their suitability in accordance with the
relevant manufacturer's instructions. In case of
doubt, ask an authorized dealer of the respective
appliance.
4. Important information
Please read the directions for use carefully and
observe the information provided. It is important to
consult these instructions in order to acquaint your-
self with the machine, its proper use and safety pre-
cautions. If you give the equipment to any other per-
son, please hand over this operating manual as well.
5. General safety instructions:
No changes may be made to the generator.
Only original parts may be used for maintenance
and accessories.
Important: Danger of poisoning, do not inhale
emissions.
Children are to be kept away from the generator.
Important: Risk of burns. Do not touch the exhaust
system or drive unit.
Never operate the generator in non-ventilated
rooms or in easyly inflammable adjacency. When
operating the generator in rooms with good venti-
lation, the exhaust gases must be channeled
directly outdoors through an exhaust hose.
Important: Toxic exhaust gases can escape
8
20.09.2006
11:27 Uhr
Seite 8
despite the exhaust hose. Due to the fire hazard,
never direct the exhaust hose towards
inflammable materials.
Risk of explosion: Never operate the generator in
rooms with combustible materials.
The speed preset by the manufacturer is not
allowed to be changed. The generator or
connected equipment may be damaged.
Secure the generator against shifting and toppling
during transport.
Place the generator at least 1m away from
buildings and the equipment connected to it.
Place the generator in a secure, level position. Do
not turn, tip or change the generator's position
while it is working.
Always switch off the engine when transporting
and refueling the generator.
Make sure that when you refuel the generator no
fuel is spilt on the engine or exhaust pipe.
Never operate the generator in rain or snow.
Never touch the generator with wet hands.
Guard against electric danger. When working
outdoors, use only extension cables that are
approved for outdoor use and which are marked
accordingly (H07RN..).
The overall length of the extension cables used
may not exceed 50 m for 1.5 mm
2.5 m
No changes may be made to the settings of the
motor or generator.
Repairs and adjustment work may only be carried
out by authorized trained personnel.
Do not refuel or empty the tank near open lights,
fire or sparks. Do not smoke!
Do not touch any mechanically driven or hot parts.
Do not remove the safety guards.
Do not expose the tools to damp or dust.
Permissible ambient temperature – 10 to + 40 °C,
max. altitude above sea level 1000 m, relative
humidity: 90 % (non-condensing)
The generator is driven by a combustion engine,
which produces heat in the area of the exhaust (on
the opposite side of the sockets) and the exhaust
outlet. You should therefore keep clear of these
surfaces because of risk of skin burns.
The values quoted in the technical data for sound
power level (LWA) and sound pressure level
(LWM) are emission values and not necessarily
reliable workplace values. As there is a
correlation between emission and immission
levels, the values are not a reliable basis for
deciding on any additional precautions which may
be needed. Factors influencing the actual user
immission level include the properties of the work
2
and 100 m for
.
2