Using the product
material) is displayed with the relevant material number (see
enclosed sticker for the inside of the protective cap).
Settable materials
1. beech, spruce, larch, birch, cherry, walnut
2. oak, pine, maple, ash-tree, douglas fir, meranti
3. cement screed, concrete
4. anhydrite screed
5. cement mortar
6. lime mortar, plaster
7. bricks
> Press
characteristic curve appears.
 Testing the instrument function:
1 Press
2 Connect sensing electrodes with the contacts of the test
resistor on the top of the protection cap.
Test
-
Test: ok
-
Test: ok
‚Tips and assistance'.
3 Press
 Changing the display view:
Adjustable views
· Current reading
· Hold: Readings are held.
Max/Min
· Max: Maximum values since the instrument was last switched on or last reset.
· Min: Minimum values since the instrument was last switched on or last reset.
> Press
 Resetting Max/Min values:
1 Press
2 Press
3 Repeat steps 1 and 2 for all values that are to be reset.
 Switching the instrument off:
> Press
several times until the desired material
several times until
flashes.
lights up: instrument is functioning.
does not light up: test not possible, see chapter
back to measurement menu.
-display for air humidity and temperature only.
several times until the desired view appears.
several times until the desired view appears.
and hold until
and hold until the display goes out.
Test:
lights up.
- - - -
appears.
Measuring range
8.8...54.8 % by weight
7.0...47.9 % by weight
0.9...22.1 % by weight
0.0...11.0 % by weight
0.7...8.6 % by weight
0.6...9.9 % by weight
0.1...16.5 % by weight