Device Operation; Operating Modes; Park Mode; Command Mode - ADEUNIS ARF8283A Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LoRaWAN DELTA P - Guide utilisateur / User guide version V1.0.0

2. DEVICE OPERATION

2.1. Operating modes

IMPORTANT NOTE: adeunis® uses the Big-Endian data format
The device has several operating modes
Send order on
serial link

COMMAND MODE

2.1.1 PARK MODE

The device is delivered in PARK mode, it is thus in standby mode and its consumption is minimal. Exit PARK mode by putting the magnet on the
"2" mentionned on the product for more than 6 seconds. The green LED lights up to indicate the detection of the magnet and then flashes
rapidly during the device start-up phase.
The device then sends its configuration and data frames (see section 4.1).
2.1.2 COMMAND MODE
This mode is used to configure the device registers. There are two ways to enter this mode:
- Open the adeunis® IoT Configurator application, connect a cable to the device's micro-USB port and connect it to the computer or mobile
phone.
- Connect a cable to the micro-USB port of the device and enter command mode via an AT command (see paragraph 3).
The output of the COMMAND mode is via the ATO command or the USB cable disconnection. The device will then return to its previous mode,
i.e. PARK or OPERATING

2.1.3 OPERATING MODE

This mode allows the device to work in its intended end use.

2.1.4 DEAD MODE

The device enters this very low power mode due to the detection of a low battery level. In this mode the device wakes up every 5 seconds to
flash the red LED twice.
Replacing the battery and then pressing and and then detecting the magnet (6 seconds) will exit this mode and return to OPERATING mode.
PARK MODE
Detection of the
magnet (6 sec)
OPERATING MODE
Automatic if battery
too low
MODE DEAD
Detection of the magnet
(6 sec)
Replacing the battery
FR
EN
Page
57
of 88

Publicité

Table des Matières
loading

Table des Matières