LoRaWAN DELTA P - Guide utilisateur / User guide version V1.0.0
S323
2
S324
2
FR
* The PIN code protects the device configuration. After 3 incorrect attempts the device is blocked.
Note concerning the register S301
EN
Caution: in order to give more freedom to the user the device has not been limited to a maximum number of backups per frame depending
on the network used. We therefore strongly recommend not exceeding the maximum number of readings authorized by the network if you
do not want to lose data (the oldest readings will be overwritten in favor of the most recent ones). If this occurs, an indication is given in the
data-frame byte status (explained in section 4.1.8).
3.3.1.02
Registers that configure the delta pressure alarm
Register
Size
(bytes)
S330
1
S331
2
S332
2
S333
2
S334
2
3.3.1.03
Registres configurant l'alarme pour l'entrée analogique 0-10 V
Register
Size
(bytes)
S350
1
S351
2
S352
2
S353
2
S354
2
Acquisition period
(reading) for analog input
0-10
Number of backups to be
made before transmitting
a frame (thus defining the
transmission period) for
analog input 0-10
Description
Alarm type chosen for the pressure
delta
Upper alarm threshold
High hysteresis
Lower alarm threshold
Low hysteresis
Description
Alarm type selected for the analog
input 0-10 V
Upper alarm threshold
High hysteresis
Lower alarm threshold
Low hysteresis
Decimal
Default: 0
Min/Max: 0 to 65535
Unit: x2 seconds
The value 300 is equivalent to one reading every 10
minutes
Decimal
Default: 0
Min/max : 0 to 65535
The value 1 = 1 frame sent for each backup
The value 0 = deactivation of the periodic mode
See note below
Encoding
Détails
Decimal
Default: 0
0: disabled
1: low threshold
2: high threshold
3: low and high thresholds
Decimal
Default: 0
Min/max : -500 to +500 (Signed value)
Unit: Pa
Decimal
Default: 0
Min/max : 0 to 500 (Unsigned value)
Unit: Pa
Decimal
See details S331
Decimal
See details S332
Encoding
Détails
Decimal
Default: 0
0: disabled
1: low threshold
2: high threshold
3: low and high thresholds
Decimal
Default: 0
Min/max : 0 to 10 000
Unit: mV
Decimal
Default: 0
Min/max : 0 to 5 000
Unit: mV
Decimal
See details S351
Decimal
See details S352
Page