Electrical installation
Warning! Only a qualified person must do
the electrical installation.
The manufacturer is not responsible if you
do not follow the safety precautions from
the chapter "Safety Information".
This appliance is only supplied with a main ca-
ble.
Cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05 RRF,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
For the section of the cable refer to the total
power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400
V three-phase with a neutral wire.
1
2

Environment concerns

Recycle the materials with the symbol
the packaging in applicable containers to
recycle it.
Help protect the environment and human health
and to recycle waste of electrical and electronic
appliances. Do not dispose appliances marked
with the symbol with the household waste.
26
A
B
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
3
4
. Put
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the con-
nection diagram below). Connect the ground
cable to the terminal. After you connect the sup-
ply cable to the terminal board, attach it with a
junction clamp.
1 2 3 4 5
230V 3~
L1
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1
1 2 3 4 5
400V 3N~
L1 L2 L3
Return the product to your local recycling facility
or contact your municipal office.
L2
L3
PE
N
PE
L2
N
PE
N
PE
www.zanussi.com