Captions:
Installation and operating instructions
Fig. 1
Set-up
and 2
1
Pump
2
Filling/venting screw plug
3
Drain screw plug
4
Diaphragm pressure vessel
5
Pressure gauge
6
Mains cable with plug (EM only)
7
Pressure switch
8
Flexible pressure hose
9
Gas filling valve
L2/P1
Spacings between fastening holes
Fig. 3a Inlet mode (tank)
6
Mains cable with plug (EM only)
10
Spring-mounted foot valve
11
Shut-off device on inlet/suction side
12
Shut-off device on the pressure side
14
Pipe attachment
16
Float switch (low water)
HC
Positive suction head
HR
Consumer height
Fig. 3b Inlet mode (supply network)
6
Mains cable with plug (EM only)
11
Shut-off device on inlet/suction side
12
Shut-off device on the pressure side
13
Non-return valve
14
Pipe attachment
15
Volume meter
HR
Consumer height
Fig. 3c Suction mode
6
Mains cable with plug (EM only)
10
Foot valve
11
Shut-off device on inlet/suction side
12
Shut-off device on the pressure side
14
Pipe attachment
16
Float switch (low water)
HA
Suction head
HR
Consumer height
Fig. 4
Set-up/installation
Fig. 5a
Lifting/Transport
and 5b
Installation and operating instructions Wilo domestic water systems HiMulti3..H.. /HMHI/HWJ
Fig. 6a
Pressure switch EM (PM)
and 6b
a
Adjusting screw for switch-off pressure
b
Adjusting screw for pressure difference
(switch-on pressure)
c
Motor cables/connections
d
Network supply line/connections
e
Earthing connections (PE)
h
Motor connection diagram WJ (EM)
i
Motor connection diagram MHI (EM)
Cable
BN Brown
colours
BU Blue
BK Black
GNYE Green-Yellow
Fig. 6c Pressure switch EM (PM) – HiMulti3 pump
a
Adjusting screw for switch-off pressure
b
Adjusting screw for pressure difference
(switch-on pressure)
c
Motor cables/connections
d
Network supply line/connections
e
Earthing connections (PE)
h
Motor terminal box (HiMulti3)
i
Quick-Connector connection (HiMulti3)
Cable
BN Brown
colours
BU Blue
BK Black
GNYE Green-Yellow
Fig. 6d Connect cable for Quick-Connector HiMulti3
Fig. 7a
Pressure switch DM (type PT)
and 7b
a
Adjusting screw for switch-off pressure
b
Adjusting screw for pressure difference
(switch-on pressure)
c
Motor supply lines/connections
d
Network supply line/connections "LINE"
(to be provided by the customer)
e
Earthing connections (PE)
j
Motor connection diagram DM (3~400 V)
k
Motor connection diagram DM (3~230 V)
Cable
BN Brown
colours
BU Blue
BK Black
GNYE Green-Yellow
Fig. 8a
Pressure switch diagrams
and 8b
Fig. 8a
Pressure switch PM5/PT5
Fig. 8b Pressure switch PM12/PT12
po
Switch-off pressure
[bar]
pi [bar] Start-up pressure
Fig. 9a
Checking gas supply pressure for diaphragm
to 9c
pressure vessel
Fig. 9a
Depressurise system
Fig. 9b Remove valve flap
Fig. 9c
Measure gas supply pressure
English
29