Gerät ausbauen
Gerät stromlos machen. Bei flächenbündig eingebauten Gerä-
ten die Silikonfuge entfernen. Muldenspanner lösen. Gerät von
unten herausdrücken.
Achtung!
Geräteschaden! Gerät nicht von oben heraushebeln.
en
Ú
Ins tal la tion i ns tru cti ons
:
Important safety information
Read these instructions carefully. Only then will you be able to
operate your appliance safely and correctly. Retain the
instruction manual and installation instructions for future use or
for subsequent owners.
The appliance can only be used safely if it is correctly installed
according to the safety instructions. The installer is responsible
for ensuring that the appliance works perfectly at its installation
location.
For the installation, observe the currently valid building
regulations and the regulations of the local electricity and gas
suppliers.
Danger of death!
Risk of poisoning from flue gases that are drawn back in.
Always ensure adequate fresh air in the room if the appliance is
being operated in exhaust air mode at the same time as room
air-dependent heat-producing appliance is being operated.
Room air-dependent heat-producing appliances (e.g. gas, oil,
wood or coal-operated heaters, continuous flow heaters or water
heaters) obtain combustion air from the room in which they are
installed and discharge the exhaust gases into the open air
through an exhaust gas system (e.g. a chimney).
In combination with an activated vapour extractor hood, room air
is extracted from the kitchen and neighbouring rooms - a partial
vacuum is produced if not enough fresh air is supplied. Toxic
gases from the chimney or the extraction shaft are sucked back
into the living space.
Adequate incoming air must therefore always be ensured.
■
An incoming/exhaust air wall box alone will not ensure
■
compliance with the limit.
Safe operation is possible only when the partial vacuum in the
place where the heat-producing appliance is installed does not
exceed 4 Pa (0.04 mbar). This can be achieved when the air
needed for combustion is able to enter through openings that
cannot be sealed, for example in doors, windows, incoming/
exhaust air wall boxes or by other technical means.
In any case, consult your responsible Master Chimney Sweep.
He is able to assess the house's entire ventilation setup and will
suggest the suitable ventilation measures to you.
Unrestricted operation is possible if the vapour extractor hood is
operated exclusively in the circulating-air mode.
Danger of death!
Risk of poisoning from flue gases that are drawn back in. If
installing a ventilation system in a room with a heat-producing
appliance connected to a chimney/flue, the electricity supply to
the hood must be equipped with a suitable safety switch.
Risk of fire!
The grease deposits in the grease filter may ignite. If the
appliance operates beside a gas-fired appliance, a ventilation
moulding must be attached when cooking. The ventilation
moulding improves the extraction behaviour for gas-fired
appliances. The ventilation moulding prevents small flames from
going out as a result of a draft.
Risk of injury!
Components inside the appliance may have sharp edges. Wear
protective gloves.
Risk of electric shock!
Components inside the appliance may have sharp edges. These
may damage the connecting cable. Do not kink or pinch the
connecting cable during installation.
Danger of suffocation!
Packaging material is dangerous to children. Never allow
children to play with packaging material.
General information
Exhaust air mode
Note: The exhaust air must not be conveyed into a functioning
smoke or exhaust gas flue or into a shaft which is used to
ventilate installation rooms which contain heat-producing
appliances.
Before conveying the exhaust air into a non-functioning smoke
■
or exhaust gas flue, obtain the consent of the heating
engineer responsible.
If the exhaust air is conveyed through the outer wall, a
■
telescopic wall box should be used.
Exhaust duct
Note: The appliance manufacturer does not assume any
warranty for complaints attributable to the pipe section.
The appliance achieves its optimum performance by means of
■
a short, straight exhaust air pipe and as large a pipe diameter
as possible.
Because of long rough exhaust air pipes, many of which are
■
pipe bends or have diameters smaller than 150 mm, the
optimum extraction performance is not achieved and fan
noise is increased.
The pipes or hoses for laying the exhaust duct must consist of
■
non-combustible material.
Round pipes
An inner diameter of 150 mm, but at least 120 mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the diameter of the
round pipes.
Ø 150 mm approx. 177 cm
Ø 120 mm approx. 113 cm
Flat ducts should have no sharp deflections.
■
Use sealing strip for deviating pipe diameters.
■
Electrical connection
: Risk of electric shock!
Components inside the appliance may have sharp edges. These
may damage the connecting cable. Do not kink or pinch the
connecting cable during installation.
Check the indoor installation before connecting the appliance.
Ensure that the indoor installation is sufficiently fused. The
voltage and frequency of the appliance must correspond to that
of the electrical installation (see rating plate).
The appliance corresponds to protection class I and must only
be operated with a protective earth connection.
An all-pole isolating switch with at least a 3 mm contact gap
must be fitted in the installation. The plug must still be
accessible after installation.
Only a qualified electrician who takes the appropriate
regulations into account may install or replace the connecting
cable.
If the power cord for the appliance becomes damaged, this
must be replaced with a special connecting cable that can be
obtained from the manufacturer or the manufacturer's customer
service department.
Installation diagram (Fig. A)
Appliance dimensions (Fig. B)
To achieve an optimum extraction output, the maximum width of
a single hob between two ventilation elements should be 60 cm.
Installation accessories
VA 420 000
Connection strip for combination with
other Vario 400 appliances for flush
installation
2
2