Deadman
When the command is received, the receiver behaves as per command 1 without executing
step by step
the stop between opening and closing. Moreover the relay is activated only for the time
during which the receiver recognizes the radio/local button code.
The relay is deactivated if the command is no longer present for 500 continuous ms or if the
maximum operating time has expired.
Deadman
When the command is received, the receiver activates the up relay. When the radio/local
up
command code is no longer received for over 500 continuous ms, or the maximum operating
time is exceeded, the receiver deactivates the relay.
Deadman
When the command is received, the receiver activates the down relay. When the radio/local
down
command code is no longer received for over 500 continuous ms, or the maximum operating
time is exceeded, the receiver deactivates the relay.
Stop
When the command is received, the receiver deactivates the up and down relay.
Up
When the command is received, the receiver activates the up relay for a maximum time equal
to the set operating time.
Down
When the command is received, the receiver activates the down relay for a maximum time
equal to the set operating time.
For all the MOTOR modes, In case of a voltage drop, when the supply is restored, the minireceiver keeps the outputs
OFF.
9) PROCEDURES
- MEMORY CLEARING (FIG. D1)
- REMOTE CONTROL MEMORY CLEARING (FIG. D2)
- SINGLE REMOTE CONTROL CLEARING (FIG. D3)
- DEVICE MODE SELECTION (FIG. D4)
- OPERATION TIMEOUT PROGRAMMING
(FIG. D5)
INSTALLATION MANUAL
10) RADIO PROCEDURES:
- LEARNING THE FIRST REMOTE CONTROL OR FUR-
THER REMOTE CONTROLS IN MOTOR MODE
(FIG. E1)
15
MIME AC -